Chapter 4 Operation and Run Instructions GK600 User Manual
- 60 -
Fig. 4-6 Parameter value setting status (b0-02 is set to 49.83Hz)
4.1.3.6 Password Authentication Status
On condition that parameters are under password protection, users would have to go through
password authentication when they want to modify function code parameter value. Only A0-00
is visible in such a state.
Under password protection, the password authentication status will be first entered upon the receipt
of pressing
in STOP parameter display status, run parameter display status, or direct
frequency modification status (refer to the setting method of parameters). It will enter parameter edit
status upon the completion of password authentication.
4.1.3.7 Direct Frequency Modification Status
In the status of STOP, fault or run, the drive will enter frequency modification status when
terminal UP/DOWN is enabled, or pressing
or
.
Fig. 4-7 Direct frequency modification status