Chapter 5 List of Parameters GK600 User Manual
- 108 -
Parameter
Designation
Scope
Factory
default
Attr
L1-01
Display parameter setting 2
on run status
Binary system setting:
0: No display
1: Display
Ones place:
BIT0: Run linear speed (m/s)
BIT1: Set linear speed (m/s)
BIT2: Input terminal status
BIT3: Output terminal status
Tens place:
BIT0: PID setting (%)
BIT1: PID feedback (%)
BIT2: Set length (m)
BIT3: Actual length (m)
Hundreds place: reserved
Thousands place: reserved
0000
△
L1-02
Display parameter setting
on stop status
Binary system setting:
0: No display
1: Display
Ones place:
BIT0: FREQ setting (Hz)
BIT1: Bus voltage (V)
BIT2: Input terminal status
BIT3: Output terminal status
Tens place:
BIT0: AI1 (V)
BIT1: AI2 (V)
BIT2: EAI (V)
BIT3: Reserved
Hundreds place:
BIT0: PID setting (%)
BIT1: PID feedback (%)
BIT2: Set length (m)
BIT3: Actual length (m)
Thousands place:
BIT0: Run linear speed (m/s)
BIT1: Set linear speed (m/s)
BIT2: External count value
BIT3: DI
Note: when this parameter value is
set to 0000, the set FREQ would be
displayed as default (Hz)
0003
△
L1-03 Linear speed COEFF
0.1%~999.9%
100.0%
△