Chapter 3 Installation and Wiring GK600 User Manual
- 24 -
ATTENTION:
Remove dust covers when mounting a drive
GK600-2T7.5B
/GK600-4T15G/18.5LB or below.
If several drives are mounted in one cabinet, parallel side-by-side mounting is
recommended.
Fig. 3-2 Minimum mounting clearances of GK600-2T11(B) and above, GK600-4T18.5G/22L(B)
and above
ATTENTION:
When mounting a drive
GK600-2T11(B)
/ GK600-4T18.5G/22L(B) or above, the minimum
mounting clearances as set forth in Table 3-1 should be assured. In case several drives are
mounted in one cabinet, parallel side-by-side mounting is recommended.
Table 3-1 Requirement of minimum mounting clearances
Drive model
Mounting clearances (mm)
A
B
GK600-2T11(B) ~ GK600-2T22(B)
GK600-4T18.5G/22L(B) ~ GK600-4T45G/55L(B)
≥50
≥200
GK600-2T30 ~ GK600-2T110
GK600-4T55G/75L(B) ~ GK600-4T500G
≥50
≥300
空气流通位置
B
空气流通位置
B
A
A
Vent clearance