Chapter 5 List of Parameters GK600 User Manual
- 98 -
Parameter
Designation
Scope
Factory
default
Attr
F0-14 PID parameter switch
0: No switch, determined by parameters
Kp1, Ti1 and Td1
1: Auto-switched on the basis of input
offset
2: Switched by terminal
0
×
F0-15
Input offset under PID
auto-switch
0.0%~100.0%
20.0%
△
F0-16 Sampling period T
0.001s~50.000s
0.002s
△
F0-17 PID offset limit
0.0%~100.0%
0.0%
△
F0-18 PID derivative limit
0.0%~100.0%
0.5%
△
F0-19 PID initial value
0.0%~100.0%
0.0%
×
F0-20
PID initial value holding
time
0.0s~3600.0s
0.0s
△
F0-21
PID feedback loss
detection value
0.0%~100.0%
0.0%
△
F0-22
PID feedback loss
detection time
0.0s~30.0s
1.0s
△
F0-23
Cutoff FREQ when opposite
to rotary set direction
0.00Hz~maximum FREQ
50.00Hz
△
F0-24 PID computation option
0: No computation in stop status
1: Computation continued in stop status
0
△
Group F1 Multi-step frequency
F1-00
FREQ set source of
multi-step 0
0: Digital setting F1-02
1: Digital setting b0-02 + control panel
∧
/
∨
adjustment
2: Digital setting b0-02 + terminal
UP/DOWN adjustment
3: AI1
4: AI2
5: EAI (on IO option)
6: X6/DI pulse input
7: Process PID output
8: Communication
0
×
F1-01
FREQ set source of
multi-step 1
0: Digital setting F1-03
1: Digital setting b0-04 + control panel
∧
/
∨
adjustment
2: Digital setting b0-04 + terminal
UP/DOWN
3: AI1
4: AI2
5: EAI (on IO option)
0
×