Chapter 6 Specification of Parameters
-
145 -
ATTENTION:
When broken-line Accel/Decel is selected, terminals "Accel/Decel time determinant 1" and
"Accel/Decel time determinant 2" will be disabled.
b2-15
Time of Accel S-curve first
segment
Range: 0.00s~60.00s
Factory default: 0.20s
b2-16
Time of Accel S-curve last
segment
Range: 0.00s~60.00s
Factory default: 0.20s
b2-17
Time of Decel S-curve first
segment
Range: 0.00s~60.00s
Factory default: 0.20s
b2-18
Time of Decel S-curve last
segment
Range: 0.00s~60.00s
Factory default: 0.20s
These four parameters are enabled when b2-12 is set to 2.
b2-19
Proportion of Accel
S-curve first segment
Range: 0.0%~100.0%
Factory default: 20.0%
b2-20
Proportion of Accel
S-curve last segment
Range: 0.0%~100.0%
Factory default: 20.0%
b2-21
Proportion of Decel
S-curve first segment
Range: 0.0%~100.0%
Factory default: 20.0%
b2-22
Proportion of Decel
S-curve last segment
Range: 0.0%~100.0%
Factory default: 20.0%
These four parameters are enabled when b2-12 is set to 3.
ATTENTION:
The sum of the values of b2-19 and b2-20 should not exceed 100.0%. The sum of the
values of b2-21 and b2-22 also should not exceed 100.0%
Group C Input and Output Terminals
Group C0 Digital Input
C0-00
Enabled condition of run
command terminals when
power up
Range: 0~1
Factory default: 0
This parameter is only for digital terminals with parameter value 1~4 (forward/reverse jog, and
forward/reverse run), and also is only for initial run after power up.
0: Trigger edge de ON detected
When run command is controlled by terminals, the drive will start to run when it detects that
the terminal electric level jumps from OFF to ON and is kept ON after power up.