PQM Power Quality Meter
GE Power Management
8.1 DNP 3.0 PROTOCOL
8 DNP COMMUNICATIONS
8
100
031C
Phase A Reactive Power Minimum
1000ths of nominal
1 unit
F4
3
101
031E
Phase A Apparent Power Minimum
1000ths of nominal
1 unit
F3
3
102
0220
Phase A Power Factor - Minimum
%
1 unit
F2
3
103
0321
Phase A Real Power - Maximum
1000ths of nominal
1 unit
F4
3
104
0323
Phase A Reactive Power Maximum
1000ths of nominal
1 unit
F4
3
105
0325
Phase A Apparent Power Maximum
1000ths of nominal
1 unit
F3
3
106
0327
Phase A Power Factor Maximum
%
1 unit
F2
3
107
0328
Phase B Real Power Minimum
1000ths of nominal
1 unit
F4
3
108
032A
Phase B Reactive Power Minimum
1000ths of nominal
1 unit
F4
3
109
032C
Phase B Apparent Power Minimum
1000ths of nominal
1 unit
F3
3
110
032E
Phase B Power Factor Minimum
%
1 unit
F2
3
111
032F
Phase B Real Power Maximum
1000ths of nominal
1 unit
F4
3
112
0331
Phase B Reactive Power Maximum
1000ths of nominal
1 unit
F4
3
113
0333
Phase B Apparent Power Maximum
1000ths of nominal
1 unit
F3
3
114
0335
Phase B Power Factor Maximum
%
1 unit
F2
3
115
0336
Phase C Real Power Minimum
1000ths of nominal
1 unit
F4
3
116
0338
Phase C Reactive Power Minimum
1000ths of nominal
1 unit
F4
3
117
033A
Phase C Apparent Power -
Minimum
1000ths of nominal
1 unit
F3
3
118
033C
Phase C Power Factor Minimum
%
1 unit
F2
3
119
033D
Phase C Real Power Maximum
1000ths of nominal
1 unit
F4
3
120
033F
Phase C Reactive Power Maximum
1000ths of nominal
1 unit
F4
3
121
0341
Phase C Apparent Power Maximum
1000ths of nominal
1 unit
F3
3
122
0343
Phase C Power Factor Maximum
%
1 unit
F2
3
123
040A
Phase A Current Demand Maximum 1000ths of nominal
1 unit
F1
3
124
040B
Phase B Current Demand Maximum 1000ths of nominal
1 unit
F1
3
125
040C
Phase C Current Demand Maximum 1000ths of nominal
1 unit
F1
3
126
040D
Neutral Current Demand Maximum
1000ths of nominal
1 unit
F1
3
127
040E
3 Phase Real Power Dmd Max
1000ths of nominal
1 unit
F4
3
128
0410
3 Phase React Power Dmd Max
1000ths of nominal
1 unit
F4
3
129
0412
3 Phase Apparent Power Dmd Max
1000ths of nominal
1 unit
F3
3
130
0441
Frequency Minimum
0.01x Hz
.01 Hz
F1
3
131
0442
Frequency Maximum
0.01x Hz
.01 Hz
F1
3
132
0482
Phase A Current THD - Maximum
0.1 x %
1 unit
F1
3
133
0483
Phase B Current THD - Maximum
0.1 x %
1 unit
F1
3
134
0484
Phase C Current THD - Maximum
0.1 x %
1 unit
F1
3
135
0485
Neutral Current THD - Maximum
0.1 x %
1 unit
F1
3
136
0486
Voltage Van THD - Maximum
0.1 x %
1 unit
F1
3
Table 8–1: POINT LIST FOR ANALOG INPUT/OUTPUT CHANGE (Sheet 4 of 5)
POINT
MOBUS
REG
DESCRIPTION
UNIT / VALUE
DEADBAND
FORMAT
CODE
EVENT CLASS
ASSIGNED TO
see footnote explanations at the end of the table
Содержание Power Quality Meter Series
Страница 2: ......
Страница 4: ......
Страница 10: ...vi PQM Power Quality Meter GE Power Management TABLE OF CONTENTS ...
Страница 29: ...GE Power Management PQM Power Quality Meter 2 5 2 INSTALLATION 2 2 ELECTRICAL 2 Figure 2 3 REAR TERMINALS ...
Страница 46: ...2 22 PQM Power Quality Meter GE Power Management 2 2 ELECTRICAL 2 INSTALLATION 2 ...
Страница 56: ...3 10 PQM Power Quality Meter GE Power Management 3 4 DEFAULT MESSAGES 3 OPERATION 3 ...
Страница 166: ...6 20 PQM Power Quality Meter GE Power Management 6 6 POWER ANALYSIS 6 SOFTWARE 6 ...
Страница 274: ...B 4 PQM Power Quality Meter GE Power Management B 1 TABLES AND FIGURES APPENDIXB B ...
Страница 276: ...C 2 PQM Power Quality Meter GE Power Management C 1 PQM WARRANTY APPENDIXC C ...
Страница 281: ...GE Power Management PQM Power Quality Meter NOTES ...