7-36
PQM Power Quality Meter
GE Power Management
7.3 MODBUS MEMORY MAP
7 MODBUS COMMUNICATIONS
7
DATA
LOGGER
LOG
NUMBERS
continued
0A61
Sa Log Number
---
---
---
F110
0 = not selected
0A62
PFa Log Number
---
---
---
F110
0 = not selected
0A63
Pb Log Number
---
---
---
F110
0 = not selected
0A64
Qb Log Number
---
---
---
F110
0 = not selected
0A65
Sb Log Number
---
---
---
F110
0 = not selected
0A66
PFb Log Number
---
---
---
F110
0 = not selected
0A67
Pc Log Number
---
---
---
F110
0 = not selected
0A68
Qc Log Number
---
---
---
F110
0 = not selected
0A69
Sc Log Number
---
---
---
F110
0 = not selected
0A6A
PFc Log Number
---
---
---
F110
0 = not selected
0A6B
P3 Log Number
---
---
---
F110
0 = not selected
0A6C
Q3 Log Number
---
---
---
F110
0 = not selected
0A6D
S3 Log Number
---
---
---
F110
0 = not selected
0A6E
PF3 Log Number
---
---
---
F110
0 = not selected
0A6F
Frequency Log Number
---
---
---
F110
0 = not selected
0A70
Positive kWh Log Number
---
---
---
F110
0 = not selected
0A71
Negative kWh Log Number
---
---
---
F110
0 = not selected
0A72
Positive kvarh Log Number
---
---
---
F110
0 = not selected
0A73
Negative kvarh Log Number
---
---
---
F110
0 = not selected
0A74
kVAh Log Number
---
---
---
F110
0 = not selected
0A75
Ia Demand Log Number
---
---
---
F110
0 = not selected
0A76
Ib Demand Log Number
---
---
---
F110
0 = not selected
0A77
Ic Demand Log Number
---
---
---
F110
0 = not selected
0A78
In Demand Log Number
---
---
---
F110
0 = not selected
0A79
P3 Demand Log Number
---
---
---
F110
0 = not selected
0A7A
Q3 Demand Log Number
---
---
---
F110
0 = not selected
0A7B
S3 Demand Log Number
---
---
---
F110
0 = not selected
0A7C
Ia THD Log Number
---
---
---
F110
0 = not selected
0A7D
Ib THD Log Number
---
---
---
F110
0 = not selected
0A7E
Ic THD Log Number
---
---
---
F110
0 = not selected
0A7F
In THD Log Number
---
---
---
F110
0 = not selected
0A80
Van THD Log Number
---
---
---
F110
0 = not selected
0A81
Vbn THD Log Number
---
---
---
F110
0 = not selected
0A82
Vcn THD Log Number
---
---
---
F110
0 = not selected
0A83
Vab THD Log Number
---
---
---
F110
0 = not selected
0A84
Vbc THD Log Number
---
---
---
F110
0 = not selected
0A85
Analog Input Log Number
---
---
---
F110
0 = not selected
0A86
Reserved
to
↓
↓
↓
↓
↓
↓
0A8F
Reserved
Table 7–10: PQM MEMORY MAP (Sheet 22 of 40)
GROUP
ADDR
(HEX)
DESCRIPTION
RANGE
STEP
VALUE
UNITS and
SCALE
FORMAT
FACTORY DEFAULT
Notes:
* Data type depends on the Command Operation Code.
** Any valid Actual Values or Setpoints address.
*** Maximum Setpoint value represents “OFF”.
**** Minimum Setpoint value represents “OFF”.
***** Maximum Setpoint value represents “UNLIMITED”.
Содержание Power Quality Meter Series
Страница 2: ......
Страница 4: ......
Страница 10: ...vi PQM Power Quality Meter GE Power Management TABLE OF CONTENTS ...
Страница 29: ...GE Power Management PQM Power Quality Meter 2 5 2 INSTALLATION 2 2 ELECTRICAL 2 Figure 2 3 REAR TERMINALS ...
Страница 46: ...2 22 PQM Power Quality Meter GE Power Management 2 2 ELECTRICAL 2 INSTALLATION 2 ...
Страница 56: ...3 10 PQM Power Quality Meter GE Power Management 3 4 DEFAULT MESSAGES 3 OPERATION 3 ...
Страница 166: ...6 20 PQM Power Quality Meter GE Power Management 6 6 POWER ANALYSIS 6 SOFTWARE 6 ...
Страница 274: ...B 4 PQM Power Quality Meter GE Power Management B 1 TABLES AND FIGURES APPENDIXB B ...
Страница 276: ...C 2 PQM Power Quality Meter GE Power Management C 1 PQM WARRANTY APPENDIXC C ...
Страница 281: ...GE Power Management PQM Power Quality Meter NOTES ...