7-28
PQM Power Quality Meter
GE Power Management
7.3 MODBUS MEMORY MAP
7 MODBUS COMMUNICATIONS
7
03FC
Reserved
to
↓
↓
↓
↓
↓
↓
03FF
Reserved
DEMAND
0400
Phase A Current Demand
---
---
A
F1
N/A
0401
Phase B Current Demand
---
---
A
F1
N/A
0402
Phase C Current Demand
---
---
A
F1
N/A
0403
Neutral Current Demand
---
---
A
F1
N/A
0404
3 Phase Real Power Demand (high)
---
---
0.01 x kW
F4
N/A
0405
3 Phase Real Power Demand (low)
---
---
0.01 x kW
F4
N/A
0406
3 Phase React Power Demand (high)
---
---
0.01 x kvar
F4
N/A
0407
3 Phase React Power Demand (low)
---
---
0.01 x kvar
F4
N/A
0408
3 Phase Apparent Power Demand (high)
---
---
0.01 x kVA
F3
N/A
0409
3 Phase Apparent Power Demand (low)
---
---
0.01 x kVA
F3
N/A
040A
Phase A Current Demand - Maximum
---
---
A
F1
N/A
040B
Phase B Current Demand - Maximum
---
---
A
F1
N/A
040C
Phase C Current Demand - Maximum
---
---
A
F1
N/A
040D
Neutral Current Demand - Maximum
---
---
A
F1
N/A
040E
3 Phase Real Power Dmd (high) - Max
---
---
0.01 x kW
F4
N/A
040F
3 Phase Real Power Dmd (low) - Max
---
---
0.01 x kW
F4
N/A
0410
3 Phase React Power Dmd (high) - Max
---
---
0.01 x kvar
F4
N/A
0411
3 Phase React Power Dmd (low) - Max
---
---
0.01 x kvar
F4
N/A
0412
3 Phase Apparent Power Dmd (high) - Max
---
---
0.01 x kVA
F3
N/A
0413
3 Phase Apparent Power Dmd (low) - Max
---
---
0.01 x kVA
F3
N/A
0414
Time - Hours/Min of Phase A Cur. Dmd Max
---
---
---
F22
N/A
0415
Time - Seconds of Phase A Cur. Dmd Max
---
---
---
F23
N/A
0416
Date - Mnth/Day of Phase A Cur. Dmd Max
---
---
---
F24
N/A
0417
Date - Year of Phase A Cur. Dmd Max
---
---
---
F25
N/A
0418
Time - Hours/Min of Phase B Cur. Dmd Max
---
---
---
F22
N/A
0419
Time - Seconds of Phase B Cur. Dmd Max
---
---
---
F23
N/A
041A
Date - Mnth/Day of Phase B Cur. Dmd Max
---
---
---
F24
N/A
041B
Date - Year of Phase B Cur. Dmd Max
---
---
---
F25
N/A
041C
Time - Hours/Min of Phase C Cur. Dmd Max
---
---
---
F22
N/A
041D
Time - Seconds of Phase C Cur. Dmd Max
---
---
---
F23
N/A
041E
Date - Mnth/Day of Phase C Cur. Dmd Max
---
---
---
F24
N/A
041F
Date - Year of Phase C Cur. Dmd Max
---
---
---
F25
N/A
0420
Time - Hours/Min of Neutral Cur. Dmd Max
---
---
---
F22
N/A
0421
Time - Seconds of Neutral Cur. Dmd Max
---
---
---
F23
N/A
0422
Date - Month/Day of Neutral Cur. Dmd Max
---
---
---
F24
N/A
0423
Date - Year of Neutral Cur. Dmd Max
---
---
---
F25
N/A
0424
Time - Hours/Min of Real Pwr Dmd Max
---
---
---
F22
N/A
0425
Time - Seconds of Real Pwr Dmd Max
---
---
---
F23
N/A
0426
Date - Month/Day of Real Pwr Dmd Max
---
---
---
F24
N/A
0427
Date - Year of Real Pwr Dmd Max
---
---
---
F25
N/A
0428
Time - Hours/Min of React Pwr Dmd Max
---
---
---
F22
N/A
Table 7–10: PQM MEMORY MAP (Sheet 14 of 40)
GROUP
ADDR
(HEX)
DESCRIPTION
RANGE
STEP
VALUE
UNITS and
SCALE
FORMAT
FACTORY DEFAULT
Notes:
* Data type depends on the Command Operation Code.
** Any valid Actual Values or Setpoints address.
*** Maximum Setpoint value represents “OFF”.
**** Minimum Setpoint value represents “OFF”.
***** Maximum Setpoint value represents “UNLIMITED”.
Содержание Power Quality Meter Series
Страница 2: ......
Страница 4: ......
Страница 10: ...vi PQM Power Quality Meter GE Power Management TABLE OF CONTENTS ...
Страница 29: ...GE Power Management PQM Power Quality Meter 2 5 2 INSTALLATION 2 2 ELECTRICAL 2 Figure 2 3 REAR TERMINALS ...
Страница 46: ...2 22 PQM Power Quality Meter GE Power Management 2 2 ELECTRICAL 2 INSTALLATION 2 ...
Страница 56: ...3 10 PQM Power Quality Meter GE Power Management 3 4 DEFAULT MESSAGES 3 OPERATION 3 ...
Страница 166: ...6 20 PQM Power Quality Meter GE Power Management 6 6 POWER ANALYSIS 6 SOFTWARE 6 ...
Страница 274: ...B 4 PQM Power Quality Meter GE Power Management B 1 TABLES AND FIGURES APPENDIXB B ...
Страница 276: ...C 2 PQM Power Quality Meter GE Power Management C 1 PQM WARRANTY APPENDIXC C ...
Страница 281: ...GE Power Management PQM Power Quality Meter NOTES ...