GE Power Management
PQM Power Quality Meter
5-29
5 MONITORING
5.4 A3 POWER ANALYSIS
5
Negative Real Power Demand Alarm/Control Dropout
3
Φ
–kW DMD
↓
Positive Reactive Power Demand Alarm/Control Pickup
3
Φ
+kvar DMD
↑
Positive Reactive Power Demand Alarm/Control Dropout
3
Φ
+kvar DMD
↓
Negative Reactive Power Demand Alarm/Control Pickup
3
Φ
–kvar DMD
↑
Negative Reactive Power Demand Alarm/Control Dropout
3
Φ
–kvar DMD
↓
Apparent Power Demand Alarm/Control Pickup
3
Φ
kVA DEMAND
↑
Apparent Power Demand Alarm/Control Dropout
3
Φ
kVA DEMAND
↓
Phase A Current Demand Alarm/Control Pickup
Ia DEMAND
↑
Phase A Current Demand Alarm/Control Dropout
Ia DEMAND
↓
Phase B Current Demand Alarm/Control Pickup
Ib DEMAND
↑
Phase B Current Demand Alarm/Control Dropout
Ib DEMAND
↓
Phase C Current Demand Alarm/Control Pickup
Ic DEMAND
↑
Phase C Current Demand Alarm/Control Dropout
Ic DEMAND
↓
Neutral Current Demand Alarm/Control Pickup
In DEMAND
↑
Neutral Current Demand Alarm/Control Dropout
In DEMAND
↓
Switch Input A Alarm/Control Pickup
SW A ACTIVE
↑
Switch Input A Alarm/Control Dropout
SW A ACTIVE
↓
Switch Input B Alarm/Control Pickup
SW B ACTIVE
↑
Switch Input B Alarm/Control Dropout
SW B ACTIVE
↓
Switch Input C Alarm/Control Pickup
SW C ACTIVE
↑
Switch Input C Alarm/Control Dropout
SW C ACTIVE
↓
Switch Input D Alarm/Control Pickup
SW D ACTIVE
↑
Switch Input D Alarm/Control Dropout
SW D ACTIVE
↓
Pulse Input 1 Alarm/Control Pickup
PULSE IN 1
↑
Pulse Input 1 Alarm/Control Dropout
PULSE IN 1
↓
Pulse Input 2 Alarm/Control Pickup
PULSE IN 2
↑
Pulse Input 2 Alarm/Control Dropout
PULSE IN 2
↓
Pulse Input 3 Alarm/Control Pickup
PULSE IN 3
↑
Pulse Input 3 Alarm/Control Dropout
PULSE IN 3
↓
Pulse Input 4 Alarm/Control Pickup
PULSE IN 4
↑
Pulse Input 4 Alarm/Control Dropout
PULSE IN 4
↓
Totalized Pulses Alarm/Control Pickup
PULSE TOTAL
↑
Totalized Pulses Alarm/Control Dropout
PULSE TOTAL
↓
Current THD Alarm/Control Pickup
CURRENT THD
↑
Current THD Alarm/Control Dropout
CURRENT THD
↓
Voltage THD Alarm/Control Pickup
VOLTAGE THD
↑
Voltage THD Alarm/Control Dropout
VOLTAGE THD
↓
Main Analog Input Alarm/Control Pickup
AN INPUT MAIN
↑
Main Analog Input Alarm/Control Dropout
AN INPUT MAIN
↓
Table 5–1: LIST OF POSSIBLE EVENTS (Sheet 2 of 3)
EVENT NAME
DISPLAYED EVENT NAME
Содержание Power Quality Meter Series
Страница 2: ......
Страница 4: ......
Страница 10: ...vi PQM Power Quality Meter GE Power Management TABLE OF CONTENTS ...
Страница 29: ...GE Power Management PQM Power Quality Meter 2 5 2 INSTALLATION 2 2 ELECTRICAL 2 Figure 2 3 REAR TERMINALS ...
Страница 46: ...2 22 PQM Power Quality Meter GE Power Management 2 2 ELECTRICAL 2 INSTALLATION 2 ...
Страница 56: ...3 10 PQM Power Quality Meter GE Power Management 3 4 DEFAULT MESSAGES 3 OPERATION 3 ...
Страница 166: ...6 20 PQM Power Quality Meter GE Power Management 6 6 POWER ANALYSIS 6 SOFTWARE 6 ...
Страница 274: ...B 4 PQM Power Quality Meter GE Power Management B 1 TABLES AND FIGURES APPENDIXB B ...
Страница 276: ...C 2 PQM Power Quality Meter GE Power Management C 1 PQM WARRANTY APPENDIXC C ...
Страница 281: ...GE Power Management PQM Power Quality Meter NOTES ...