CHAPTER 2 WIRING
Description of I/O Signals
2-83
2
Parameter
setting
Enter the corresponding value (“79”) to the output terminal function setting parameter. Relevant
signal reference values are shown below.
Signal No.
Immediate value continuation: sequence input
signal
22
Immediate value continuation permission:
sequence output signal
79
Immediate value continuation completion:
sequence output signal
80
Immediate value continuation completion: Sequence output signal (Reference value 80)
The signal is turned on after continuation of immediate value operation is processed according to an
immediate value continuation command, and it is turned off after the immediate value continuation
command is turned off.
Function
After immediate value operation is started and positioning is completed, the positioning motion
continues according to new target position (speed) data. The positioning motion continues even if
deceleration is already started with immediate value operation data.
For details, refer to “Immediate value continuation.”
Parameter
setting
Enter the corresponding value (“80”) to the output terminal function setting parameter. The relevant
signal reference values are shown below.
Allocated signal
No.
Immediate value continuation: sequence input
signal
22
Immediate value continuation permission:
sequence output signal
79
Immediate value continuation completion:
sequence output signal
80
Immediate value change completion: Sequence output signal (Reference value 81)
The signal is turned on when the changing process is executed according to an immediate value
change signal, and it is turned off after the immediate value change is turned off.
Function
While the in-position signal is turned off after immediate value operation is started, the target
position and target speed can be changed at an arbitrary timing.
For details, refer to “Immediate value change.”
The command position and command speed change at the activating edge of the immediate value
change command. While the positioning completion signal is turned off, they can be changed at an
arbitrary timing.
Содержание ALPHA5 Smart
Страница 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Страница 2: ......
Страница 4: ...ii...
Страница 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Страница 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Страница 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Страница 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Страница 405: ...CHAPTER 8 SPECIFICATIONS Specifications of Servo Amplifier 8 13 8 8 2 2 Interface Specifications...
Страница 411: ...CHAPTER 8 SPECIFICATIONS Dimensions of Servo Amplifier 8 19 8 8 4 Dimensions of Servo Amplifier...
Страница 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Страница 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Страница 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Страница 595: ...CHAPTER 15 APPENDIXES Main Circuit Block Diagram 15 3 15 15 2 Main Circuit Block Diagram Applicable model Frame1...
Страница 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Страница 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Страница 635: ......