CHAPTER 10 PERIPHERAL EQUIPMENT
10-16
AC Reactor
10
10.7 AC Reactor
Connect an AC reactor in following cases.
(1) Large power supply capacity
With power supply capacities exceeding 500 kVA, the power-on input current fed to the servo
amplifier may become too large and cause damage to the internal rectifying diode.
(The power supply capacity depends on the 20 m wiring length and the designated cable size.)
(2) Imbalance in source voltage
If there is imbalance in the source voltage, the current gathers to the phase of a higher voltage.
Connect the AC reactor if the ratio of voltage imbalance is 3% or above.
(Ratio of power supply imbalance) =
× 100
Insert an AC reactor to balance the input current among phases. The AC reactor also provides
protection against loss of source voltage or similar hazards.
(3) Suppression of harmonics
The servo amplifier generates harmonics currents because it is a capacitor input type. The AC
reactor suppresses current distortion in the power supply system, protecting devices in the same
system against damage. Imbalance in the source voltage increases harmonics currents.
Insert an AC reactor in the primary circuit of the servo amplifier. Heat generation is caused with
types of a small rated conductive current, and the suppression effect is reduced with types of a
large rated conductive current.
(Max. voltage [V]) - (Min. voltage [V])
(Average voltage of threV])
Содержание ALPHA5 Smart
Страница 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Страница 2: ......
Страница 4: ...ii...
Страница 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Страница 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Страница 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Страница 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Страница 405: ...CHAPTER 8 SPECIFICATIONS Specifications of Servo Amplifier 8 13 8 8 2 2 Interface Specifications...
Страница 411: ...CHAPTER 8 SPECIFICATIONS Dimensions of Servo Amplifier 8 19 8 8 4 Dimensions of Servo Amplifier...
Страница 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Страница 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Страница 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Страница 595: ...CHAPTER 15 APPENDIXES Main Circuit Block Diagram 15 3 15 15 2 Main Circuit Block Diagram Applicable model Frame1...
Страница 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Страница 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Страница 635: ......