CHAPTER 11 ABSOLUTE POSITION SYSTEM
11-2
Specifications
11
11.1 Specifications
11.1.1 Specification List
Item Description
Method
Battery backup method
Battery Lithium
battery (primary battery, n3.6 V)
Max. rotation range
Home position ±32767 rev
Max. rotation speed at power
failure
6000 r/min
Service life of battery
About 35000 hours (life without power turned on)
It is recommended to replace the battery periodically (every three years or more
frequently) despite the power-on or shutdown state.
11.1.2 Precautions
Marine or air transport of battery (lithium-metal battery)
The following precautions must be taken when you transport lithium-metal batteries in any of the
conditions of the followings: individually, packaged with the devices, or mounted in devices.
1) When transporting lithium-metal batteries mounted in devices
When transporting the batteries together with a control panel or the like instrumented with five or
more servo amplifiers into which the batteries are mounted, attach the label Fig. 1 below and
submit the transportation documents.
2) When transporting lithium-metal batteries packaged with devices
It is necessary to attach the label Fig. 1 below and submit the transportation documents to issue
the drop test certificate.
Furthermore, the allowable number of the batteries to be transported by air is the number
required to operate the device plus two.
Fig.1 Label to be attached to the package outer surface
Size
: 120 ×110 mm
For details contact us or Fuji Electric Systems representative.
Conditions blocking establishment of absolute position system
The absolute position system is not established under the following conditions.
The electronic gear setting is changed after position preset.
The command pulse ratio is changed after position preset.
The absolute position system can be established even under speed control or torque control.
Содержание ALPHA5 Smart
Страница 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Страница 2: ......
Страница 4: ...ii...
Страница 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Страница 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Страница 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Страница 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Страница 405: ...CHAPTER 8 SPECIFICATIONS Specifications of Servo Amplifier 8 13 8 8 2 2 Interface Specifications...
Страница 411: ...CHAPTER 8 SPECIFICATIONS Dimensions of Servo Amplifier 8 19 8 8 4 Dimensions of Servo Amplifier...
Страница 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Страница 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Страница 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Страница 595: ...CHAPTER 15 APPENDIXES Main Circuit Block Diagram 15 3 15 15 2 Main Circuit Block Diagram Applicable model Frame1...
Страница 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Страница 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Страница 635: ......