CHAPTER 4 PARAMETER
Automatic Operation Setting Parameter
4-49
4
PA2_22 Detection time for contact-stopper
PA2_23 Torque limit for contact-stopper
No. Name
Setting
range
Default
value
Change
22
Detection time for
contact-stopper
0 to 10000 [ms]
0
Always
23
Torque limit for
contact-stopper
0 to 100 [%]
0
Always
These parameters are enabled if “5” (stopper) is selected for PA2_11 (home position shift amount
reference signal).
Enter these parameters to perform homing in applications such as positioning of a cylinder or the like
where the home position LS or +/-OT cannot be used.
Enter the detection time and the torque limit on contact with the stopper.
For details, refer to “(7) Homing Pattern Using the Stopper” on page 4-67.
PA2_24 Selection of operation at OT detection during homing
No. Name
Setting
range
Default
value
Change
24
Selection of operation at
OT during homing
0: Reverse rotation
1: Stop and cancel the homing
0 Power
Specify the motion taken upon first OT detection during homing motion.
Specify 0 to reverse the motion upon first OT detection.
Specify 1 to cancel homing and stop upon detection of OT.
Parameters related to homing
PA1_12 (Z-phase position offset)
No. Name
Setting
range
Default
value
Change
12
Z-phase position offset 0 to 1048575 [pulses]: 20 bits
0
Power
The encoder Z-phase position can be adjusted.
The Z-phase output position shifts by the pulse amount (pulse units) specified in the CCW
direction.
If the encoder Z-phase is selected as a reference signal for shift operation, adjust the encoder
Z-phase position with this parameter after motor replacement so that homing can be made to the
original position without changing the reference signal for homing (deceleration starting signal) or
homing parameters.
For details, refer to "PA1_12 Z-phase position offset" on page 4-14.
Homing speed
Speed
Time
+OT
OFF
+
-
ON
Selection of operation at OT detection during homing = 0
Homing speed
Speed
Time
+OT
+
-
ON
Selection of operation at OT detection during homing = 1
In-position
OFF ON
OFF
In-position
OFF
ON
OFF OFF
Содержание ALPHA5 Smart
Страница 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Страница 2: ......
Страница 4: ...ii...
Страница 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Страница 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Страница 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Страница 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Страница 405: ...CHAPTER 8 SPECIFICATIONS Specifications of Servo Amplifier 8 13 8 8 2 2 Interface Specifications...
Страница 411: ...CHAPTER 8 SPECIFICATIONS Dimensions of Servo Amplifier 8 19 8 8 4 Dimensions of Servo Amplifier...
Страница 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Страница 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Страница 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Страница 595: ...CHAPTER 15 APPENDIXES Main Circuit Block Diagram 15 3 15 15 2 Main Circuit Block Diagram Applicable model Frame1...
Страница 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Страница 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Страница 635: ......