CHAPTER 4 PARAMETER
4-60
Automatic Operation Setting Parameter
4
(4) Reference signal for shift operation homing profile (equivalent to homing profile 4 of FALDIC-
α
Series)
Upon detection of a reference signal for shift operation after the start of homing, the motion
reverses to the point ahead of the reference signal for shift operation, and then the motion
continues at the creep speed for homing to detect the reference signal for shift operation and
determine the home position.
Accurate homing (highly reproducible zero position) is realized only with the reference signal for
shift operation without using the reference signal for homing (deceleration starting signal).
[Parameter setting example]
PA1_
No. Name
Setting
Default
value
Change
01
Control mode selection
6: Extension mode
0
Power
PA2_
No. Name
Setting
Default
value
Change
06
Homing speed
500.00 [r/min]
500.00
Always
07
Creep speed for homing
50.00 [r/min]
50.00
Always
08
Starting direction for homing
0: Forward rotation
0
Power
09
Reverse traveling unit amount for
homing
0 [units]
0
Always
10
Homing direction after reference signal
detection
0: Forward rotation
0
Power
11
Reference signal for shift operation
0: Home position LS
1
Power
13
Home position LS signal edge selection 0: Rising edge
0
Power
14
Home position shift unit amount
1000 [units]
1000
Always
15
Deceleration operation for creep speed
1: Reverse rotation is
enabled
0 Power
16
Home position after homing completion 0 [units]
0
Always
17
Home position detection range
0: Always ON after homing
completion
0 Always
18
Deceleration time at OT during homing 100.0 [ms]
100.0
Always
24
Selection of operation at OT during
homing
0: Reverse rotation
0 Power
Because rotation reverses in the direction opposite to the OT direction upon OT detection to
detect the reference signal for homing (deceleration starting signal) and reference signal for shift
operation, homing can be secured. The reverse rotation after OT detection follows (2) OT
reference homing profile.
Содержание ALPHA5 Smart
Страница 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Страница 2: ......
Страница 4: ...ii...
Страница 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Страница 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Страница 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Страница 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Страница 405: ...CHAPTER 8 SPECIFICATIONS Specifications of Servo Amplifier 8 13 8 8 2 2 Interface Specifications...
Страница 411: ...CHAPTER 8 SPECIFICATIONS Dimensions of Servo Amplifier 8 19 8 8 4 Dimensions of Servo Amplifier...
Страница 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Страница 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Страница 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Страница 595: ...CHAPTER 15 APPENDIXES Main Circuit Block Diagram 15 3 15 15 2 Main Circuit Block Diagram Applicable model Frame1...
Страница 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Страница 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Страница 635: ......