4.4.1 List (PA2_
)
Control mode
No.
PA2_
Name Default
value
Power
Position
Speed
Torque
Record of
reference
value
01
Decimal point position of
positioning data
0 -
06
Homing speed
500.00
-
- -
07
Creep speed for homing
50.00
-
- -
08
Starting direction for homing
0
- -
09
Reverse traveling unit amount for
homing
0 -
- -
10
Homing direction after reference
signal detection
0
- -
11
Reference signal for shift operation
1
- -
12
Reference signal for homing
(Deceleration starting signal)
0
- -
13
Home position LS signal edge
selection
0
- -
14
Home position shift unit amount
1000
-
- -
15
Deceleration operation for creep
speed
0
- -
16
Home position after homing
completion
0 -
- -
17
Home position detection range
0
- -
18
Deceleration time at OT during
homing
100.0 -
- -
19
Preset position
0
-
- -
20
Interrupt traveling unit amount
100000
-
- -
22
Detection time for contact-stopper
0
-
○
- -
23
Torque limit for contact-stopper
0
-
○
- -
24
Selection of operation at OT
detection during homing
0
25
Software OT selection (PA1_01=1
to 6) / Positioning operation type
(PA1_01=7)
0
-
26
Positive software OT detection
position
2000000000 -
-
27
Negative software OT detection
position
-2000000000 -
-
28
Positive limiter detection time
2000000000
-
○
- -
29
Negative limiter detection time
-2000000000
-
○
- -
31
Point detection, area detection
0
-
32
Point detection, area detection
position 1
0 -
33
Point detection, area detection
position 2
0 -
34
Point detection range
100
-
Содержание ALPHA5 Smart
Страница 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Страница 2: ......
Страница 4: ...ii...
Страница 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Страница 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Страница 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Страница 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Страница 405: ...CHAPTER 8 SPECIFICATIONS Specifications of Servo Amplifier 8 13 8 8 2 2 Interface Specifications...
Страница 411: ...CHAPTER 8 SPECIFICATIONS Dimensions of Servo Amplifier 8 19 8 8 4 Dimensions of Servo Amplifier...
Страница 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Страница 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Страница 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Страница 595: ...CHAPTER 15 APPENDIXES Main Circuit Block Diagram 15 3 15 15 2 Main Circuit Block Diagram Applicable model Frame1...
Страница 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Страница 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Страница 635: ......