![Fuji Electric ALPHA5 Smart Скачать руководство пользователя страница 233](http://html1.mh-extra.com/html/fuji-electric/alpha5-smart/alpha5-smart_user-manual_2341955233.webp)
CHAPTER 4 PARAMETER
Automatic Operation Setting Parameter
4-65
4
If PA2_08 = “2” and neither of the above conditions is satisfied, the starting direction for homing
follows the setting of PA2_10 (homing direction after reference signal detection). If PA2_08 is set
at “2,” PA2_09 (reverse traveling unit amount for homing) is internally handled as zero forcibly.
Operation proceeds in the following order.
(1) Condition judgment start is made upon the rising edge (OFF-to-ON transition) of homing
[ORG] in the reverse rotation direction at the zero return speed (PA2_06).
(2) Upon deactivation of home position LS (PA2_12, PA2_13), movement is temporarily stopped,
then continues in the homing direction after reference signal detection (PA2_10) at the creep
speed for homing (PA2_07).
(3) The travel continues by the home position shift unit amount (PA2_14) after the first encoder
Z-phase (PA2_11) is detected since the home position LS (PA_12) is detected, followed by
stoppage. The stopping point changes to the home position and homing completion is turned
on, finishing the homing process.
Homing speed
[PA2_06]
Creep speed for homing [PA2_07]
Time
Homing [ORG]
OFF ON
OFF
Home position LS
[LS]
OFF
ON
ON
Encoder
Z-phase
ON
OFF
Home position shift unit amount
[PA2_14]
Servo-on [S-ON]
OFF ON
Ready for servo-on
OFF ON
Homing LS detection
OFF
ON
OFF
Homing completion
OFF
ON
Zero
speed
OFF
ON ON
In-position
[INP]
OFF
ON ON
OFF
Controller,
sensor
↓
Servo amplifier
Servo amplifier
↓
Controller
Position control
OFF ON
(1)
(2)
(3)
+
-
ON
ON
OFF
OFF
Home position LS
Encoder Z-phase
Home position
Starting direction for homing
Home position shift amount
(1)
(2)
(3)
Homing direction after reference signal detection
Speed
Содержание ALPHA5 Smart
Страница 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Страница 2: ......
Страница 4: ...ii...
Страница 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Страница 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Страница 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Страница 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Страница 405: ...CHAPTER 8 SPECIFICATIONS Specifications of Servo Amplifier 8 13 8 8 2 2 Interface Specifications...
Страница 411: ...CHAPTER 8 SPECIFICATIONS Dimensions of Servo Amplifier 8 19 8 8 4 Dimensions of Servo Amplifier...
Страница 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Страница 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Страница 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Страница 595: ...CHAPTER 15 APPENDIXES Main Circuit Block Diagram 15 3 15 15 2 Main Circuit Block Diagram Applicable model Frame1...
Страница 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Страница 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Страница 635: ......