CHAPTER 3 OPERATION
Operation
3-13
3
3.4.6 Extension Mode
Compatible mode with standard type of FALDIC-
Series
If parameter PA1_01 is “6,” operation is made with control signal inputs similar to those of the
Series.
If the pulse operation is performed, pulses are active while "position control" and "pulse ratio 1 (2)" are
turned on.
Command pulse multiplication (PA1_01 = 0)
Numerator 0 of electronic gear (PA1_06), numerator 1 of electronic gear (PA2_51), numerator 2 of
electronic gear (PA2_52) or numerator 3 of electronic gear (PA2_53) with an input signal can be
selected.
Position
control
The following signals are enabled in the position control mode.
Zero deviation
The difference between the command position (pulse input) and feedback position (present
motor position) is the deviation. The signal is turned on if the present deviation is below a certain
value. You can check that the motor has reached the command position.
Zero speed
The signal is turned on if the feedback speed of the motor (present shaft rotation speed of motor)
is below a certain value.
In-position
Parameter PA1_34 to switch between level output and single-shot output can be used. The level
output is the same as the zero deviation signal, The single-shot output is turned on for a certain
time after the zero deviation signal is turned on.
OFF
OFF
ON
About 2 ms
About 2 ms
[S-ON]
[RDY]
Position control
ON
ON
Pulse enable
Disable
Disable
Input
enable/disable
Pulse ratio 1
ON
Содержание ALPHA5 Smart
Страница 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Страница 2: ......
Страница 4: ...ii...
Страница 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Страница 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Страница 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Страница 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Страница 405: ...CHAPTER 8 SPECIFICATIONS Specifications of Servo Amplifier 8 13 8 8 2 2 Interface Specifications...
Страница 411: ...CHAPTER 8 SPECIFICATIONS Dimensions of Servo Amplifier 8 19 8 8 4 Dimensions of Servo Amplifier...
Страница 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Страница 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Страница 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Страница 595: ...CHAPTER 15 APPENDIXES Main Circuit Block Diagram 15 3 15 15 2 Main Circuit Block Diagram Applicable model Frame1...
Страница 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Страница 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Страница 635: ......