![Fuji Electric ALPHA5 Smart Скачать руководство пользователя страница 209](http://html1.mh-extra.com/html/fuji-electric/alpha5-smart/alpha5-smart_user-manual_2341955209.webp)
CHAPTER 4 PARAMETER
Automatic Operation Setting Parameter
4-41
4
No. Name
Setting
range
Default
value
Change
17
Home position detection range
0: Always ON after homing completion
1 to 2000000000 [units]
0 Always
18
Deceleration time at OT during homing 0.0 to 99999.9 [ms]
100.0
Always
22
Detection time for contact-stopper
0 to 10000 [ms]
0
Always
23
Torque limit value for contact-stopper 0 to 100 [%]
0
Always
24
Selection of operation at OT during
homing
0: Reverse rotation
1: Stop and cancel the homing
0 Power
*: Compulsory setting item
ALPHA5 smart can combine parameter settings to create the desired homing profile.
The homing profile is configured with combination of the following parameters.
(1) Starting direction for homing
Specify the starting direction (forward/reverse rotation) of homing. The direction opposite to the
homing direction after reference signal detection can be specified.
(2) Homing direction after reference signal detection
Select the side of the home position (forward or reverse rotation side) in relation to the reference
signal for homing (Deceleration starting signal) and reference signal for shift operation.
(3) Reference signal for shift operation
Select the signal serving as the direct standard of the zero position. You can OT or -OT.
(4) Reference signal for homing (Deceleration starting signal)
Specify the creep speed deceleration signal that is used if the encoder Z-phase is selected as a
reference signal for shift operation. You can select LS, +OT or -OT. When the encoder Z-phase
is selected, It becomes the creep speed from the start of homing operation.
Содержание ALPHA5 Smart
Страница 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Страница 2: ......
Страница 4: ...ii...
Страница 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Страница 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Страница 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Страница 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Страница 405: ...CHAPTER 8 SPECIFICATIONS Specifications of Servo Amplifier 8 13 8 8 2 2 Interface Specifications...
Страница 411: ...CHAPTER 8 SPECIFICATIONS Dimensions of Servo Amplifier 8 19 8 8 4 Dimensions of Servo Amplifier...
Страница 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Страница 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Страница 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Страница 595: ...CHAPTER 15 APPENDIXES Main Circuit Block Diagram 15 3 15 15 2 Main Circuit Block Diagram Applicable model Frame1...
Страница 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Страница 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Страница 635: ......