CHAPTER 12 POSITIONING DATA
12-14
Startup
12
Operation with immediate value data
When immediate value data are directly set by the RS-485 communications, if the start positioning
signal is set, positioning is started according to the setting.
This operation differs from the operation with positioning data in the continuation function and
setup of the stand still timer.
For the continuation function, a similar function can be realized by assigning the immediate value
continuation to the CONT signal.
In addition, if you wish to change data immediately during operation, the function of the immediate
value change is usable.
For the function of the stand still timer, adjust timing using the host controller.
For details, refer to
“
CHAPTER 13
RS-485 COMMUNICATIONS
”
.
Stop
method
The servo motor is decelerated before the specified position set by positioning data, and stopped
automatically at that position.
The method for stopping the motor forcibly after moving has started is as follows:
Turn off the operation command [RUN].
Turn off the forced stop [EMG].
Turn on the positioning cancel.
Turn off the external error input.
Turn on the pause (By turning it off, the remaining operation is executed).
Turn on free run.
After the motor has started moving, if one of the signals below is detected, the specified position of
positioning data might not be reached.
Software OT (overtravel), +OT, and -OT signals
Limiter detection
Содержание ALPHA5 Smart
Страница 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Страница 2: ......
Страница 4: ...ii...
Страница 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Страница 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Страница 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Страница 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Страница 405: ...CHAPTER 8 SPECIFICATIONS Specifications of Servo Amplifier 8 13 8 8 2 2 Interface Specifications...
Страница 411: ...CHAPTER 8 SPECIFICATIONS Dimensions of Servo Amplifier 8 19 8 8 4 Dimensions of Servo Amplifier...
Страница 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Страница 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Страница 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Страница 595: ...CHAPTER 15 APPENDIXES Main Circuit Block Diagram 15 3 15 15 2 Main Circuit Block Diagram Applicable model Frame1...
Страница 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Страница 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Страница 635: ......