Error solving manual.
CNC 8060
CNC 8065
·31·
(R
EF
: 1709)
1154
'File name too long'
DETECTION
During execution.
CAUSE
The file name has too many characters. The name of a program or subroutine may
have a maximum of 63 characters and the path 120. When programming the name
of a program or subroutine with the path, the maximum number of characters will be
the sum of both values.
SOLUTION
Decrease the number of characters of the name of the program or subroutine.
Change the location of the program or subroutine to reduce the number of characters
of the path.
1155
'No access to the file'
DETECTION
During execution.
CAUSE
The CNC cannot access the program or subroutine.
SOLUTION
Check that the files are valid and are not corrupted. When calling subroutines, check
that the name and the path are correct. If the path is not defined in the call to the
subroutine, the CNC will apply the default search criterion (see the programming
manual).
1156
'Main program not found'
DETECTION
During execution.
CAUSE
The CNC cannot find the main program.
SOLUTION
In a program with local subroutines, the main program must have a name (%name).
1157
'Global subroutine not found'
DETECTION
During execution.
CAUSE
The CNC cannot find the global subroutine.
SOLUTION
Check that the name and the path of the subroutine are correct. If the path is not
defined in the call to the subroutine, the CNC will apply the default search criterion
(see the programming manual).
1159
'Name of the local subroutine too long'
DETECTION
During execution.
CAUSE
The subroutine name has too many characters. The name of a subroutine may have
a maximum of 63 characters.
SOLUTION
Check the program.
1160
'Local subroutine not found'
DETECTION
During execution.
CAUSE
The CNC cannot find the local subroutine.
SOLUTION
Check the name of the local subroutine in the calling block is the same as the name
that appears in its definition. The local subroutines must be defined at the beginning
of the program.
1161
'$ control blocks open'
DETECTION
During execution.
CAUSE
The CNC has found a "$" control block that does not have its corresponding closing
instruction.
SOLUTION
Check the program.
1162
'M17/M29/#RET not expected'
DETECTION
During execution.
CAUSE
The CNC has detected an M17, M29 function or #RET as end of program.
SOLUTION
Program M30/M02 as the end of the main program. If the error persists, check that
all the local subroutines end with M17, M29 or #RET.
1163
'M30/M02 not expected'
DETECTION
During execution.
CAUSE
The CNC has detected an M02 or M30 function as end of program.
SOLUTION
Check that all the local and global subroutines end with M17, M29 or #RET.
1164
'Unknown term in mathematical expression'
DETECTION
During execution.
CAUSE
The mathematical expression is wrong.
SOLUTION
Check all the terms of the expression; variables, parameters, operators, etc.
Содержание 8065
Страница 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Страница 4: ...BLANK PAGE 4...
Страница 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Страница 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Страница 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Страница 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...