'Communication time out'
DETECTION
During execution.
CAUSE
The CNC does not end successfully the reading / writing of an external variable.
SOLUTION
If the error persists, contact your supplier.
0105
'Parameters cannot be validated while executing a program'
DETECTION
During execution.
CAUSE
The user has tried to validate a machine parameter table while a part-program is in
execution or interrupted.
SOLUTION
Wait for the program execution to finish or cancel the program execution in all the
channels.
0106
'Parameters cannot be validated Spindle or axis moving'
DETECTION
During the validation of the machine parameters.
CAUSE
The user has tried to validate a machine parameter table while a spindle or an axis
is moving. An axis may be moving as a result of a command of independent axis.
SOLUTION
Stop the axis or spindle movement.
0107
'Error when registering DRV variables'
DETECTION
During the validation of the machine parameters.
CAUSE
The CNC has generated an error when trying to register the variables defined in the
OEM parameters table.
SOLUTION
Contact Fagor.
0108
'Oscillo: The sampling time cannot be readjusted with the new LOOPTIME'
DETECTION
During execution.
CAUSE
The user has used the oscilloscope without validating a trace, has modified
parameter LOOPTIME and has validated the machine parameters.
SOLUTION
The warning will no longer be displayed when the user executes a trace at the
oscilloscope. Setting the sampling period of a trace of the oscilloscope depends on
parameter LOOPTIME. In order for the CNC to be able to set this, it must have a
validated trace of the oscilloscope; i.e. the trace must have been executed at least
once.
0109
'Parameters cannot be validated: spindle in synchronization'
DETECTION
On CNC power-up or when validating the machine parameters or when compiling the
PLC program.
CAUSE
The CNC does not admit this type of actions with active synchronized spindles
because they require a system reset.
SOLUTION
The parameters must be validated or the PLC program must be compiled before
synchronizing the spindles or the spindles must be momentarily de-synchronized in
order to carry out the desired action.
0110
'The user kinematics could not be loaded'
DETECTION
During CNC startup.
CAUSE
The CNC does not show the file \windows\system32\drivers\kinematic.sys.
SOLUTION
Checks that no errors come up when doing the make of the user kinematics and that
the kinematic.sys driver is generated correctly.
0111
'Error when initializing user kinematics data'
DETECTION
During CNC startup.
CAUSE
Error in the function for initializing and loading the user kinematics data
(UserTransforDataInit) implemented in the file Kin_iniData.c.
SOLUTION
Check and correct the possible reasons why this function generates an error.
0112
'Error when initializing user kinematics'
DETECTION
When activating a user kinematics.
CAUSE
Error in the function for initializing the kinematics (UserTransforInit) implemented in
the file Kin_impl.c.
SOLUTION
Check and correct the possible reasons why this function generates an error.
Содержание 8065
Страница 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Страница 4: ...BLANK PAGE 4...
Страница 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Страница 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Страница 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Страница 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...