![Fagor 8065 Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/fagor/8065/8065_error-solving-manual_3194234151.webp)
Error solving manual.
CNC 8060
CNC 8065
·151·
(R
EF
: 1709)
5010
'Division by zero at the PLC'
DETECTION
When executing a DVS or MDS instruction.
CAUSE
The denominator of a DVS or MDS operation is 0.
SOLUTION
Check the PLC program. Do not divide by 0.
5013
'Error when reading the PLC digital inputs'
DETECTION
When reading the digital inputs of the PLC.
CAUSE
The digital I/O configuration table is wrong.
SOLUTION
Check the digital I/O configuration table. If the error persists, contact Fagor.
5014
'Error when writing the PLC digital outputs'
DETECTION
When writing the digital outputs of the PLC.
CAUSE
The table to set the digital I/O is wrong or the PLC has received a writing request
before finishing the previous one.
SOLUTION
Check the table to set the digital I/O, runs the pertinent checks to ensure the integrity
of the CAN bus or raise the cycle time in parameter PLCFREQ. If the error persists,
contact Fagor.
5015
'The variable could not be read from the PLC'
DETECTION
When executing a CNCRD instruction.
CAUSE
Reading a global or local arithmetic parameter that does not exist.
SOLUTION
Check the settings of global and local parameters as well as the PLC program.
5016
'Reading value out of range'
DETECTION
When executing a CNCRD instruction.
CAUSE
Data read out of range.
SOLUTION
Check the syntax of the instruction.
5017
'Null CNCEX block'
DETECTION
When executing a CNCEX instruction.
CAUSE
The block programmed in the CNCEX instruction is null or the programmed channel
is not available.
SOLUTION
Check the block to be executed and the status of the channel.
5018
''CNCEX has not been executed because the communication mark is set to "1"'
DETECTION
When executing a CNCEX instruction.
CAUSE
The mark programmed in the CNCEX instruction is already active when executing
the instruction. It may be because the instruction has been programmed wrong or
because the channel is busy with another CNCEX instruction.
SOLUTION
Check, in the PLC program, the logic of the CNCEX instruction and of the marks used.
5019
'CNCEX: Execution channel not available'
DETECTION
When executing a CNCEX instruction.
CAUSE
The channel programmed in the CNCEX instruction is not available. The channel is
executing another block, another program or is in a wrong state.
SOLUTION
Check the status of the channel programmed in the CNCEX instruction.
5020
'CNCEX: Execution incomplete'
DETECTION
When executing a CNCEX instruction.
CAUSE
The CNCEX instruction cannot execute the block in the indicated channel.
SOLUTION
Check the status of the channel programmed in the CNCEX instruction.
5021
'CNCEX: The indicated channel is not a PLC channel'
DETECTION
When executing a CNCEX instruction.
CAUSE
The channel programmed in the CNCEX instruction is not a PLC channel.
SOLUTION
Check the syntax of the instruction. Check the type of channel in the machine
parameters (parameter CHTYPE).
Содержание 8065
Страница 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Страница 4: ...BLANK PAGE 4...
Страница 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Страница 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Страница 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Страница 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...