100/180 mm PAPERLESS GRAPHIC RECORDER: USER GUIDE
HA028910
Issue 13 Sep 16
User Guide
Page 340
12.3 CONFIGURATION
Confi guration takes place in two areas
viz
: ‘Connections’ and ‘Reports’ (
section 12.3.2
).
12.3.1 Connections
Figure 12.3.1a shows the default confi guration page for ASCII printer protocol. See
section 4.3.15
for
other protocols.
Figure 12.3.1a Serial communications confi guration menu
Connection
Baud Rate
Stop Bits
Parity
Printer Type
Printer Name
Printer Status
System
Alarms
Power Up
Select required Baud rate.
Select 1 or 2
Link Error Count
Reset Error Count
Select printer type
Printer Test
Print Messages From
Messages To Print
General
Batches
Logins
Apply
Discard
Port
Online
Protocol
EIA232
9600
1
Even
Star TSP600
0
Star TSP600(0)
Not Responding
1) Group 1
Serial 1
ASCII Printer
PORT
This allows serial port 1 or serial port 2 to be selected for printer confi guration. Separate, independently
confi gurable printers can be connected to the two ports, or, if only one printer is to be connected, any of
the other available protocols can be selected for the non-printer port.
LINK ERROR COUNT
The counter is incremented every time there is a framing error, a parity error or a Cyclic redundancy
check (CRC) error whilst communicating with the printer. The ‘Reset Error Count’ key is used to reset the
count to zero.
Note: For instruments fi tted with two printers, the count relates to the currently selected printer.