Diagnostics and troubleshooting
Proline Cubemass C 300
164
Hauser
Parameter
Prerequisite
Description
User interface
Operating time from restart
–
Shows the time the device has been in
operation since the last device restart.
Days (d), hours (h),
minutes (m) and seconds
(s)
Operating time
–
Indicates how long the device has been
in operation.
Days (d), hours (h),
minutes (m) and seconds
(s)
12.9 Diagnostic list
Up to 5 currently pending diagnostic events can be displayed in the
Diagnostic list
submenu along with the associated diagnostic information. If more than 5 diagnostic
events are pending, the events with the highest priority are shown on the display.
Navigation path
Diagnostics → Diagnostic list
Diagnostics
/ ../Diagnose list
Diagnostics 3
Diagnostics 2
F273 Main electronic
A0014006-EN
36
Taking the example of the local display
To call up the measures to rectify a diagnostic event:
• Via "FieldCare" operating tool → 157
• Via "DeviceCare" operating tool → 157
12.10 Event logbook
12.10.1 Reading out the event logbook
A chronological overview of the event messages that have occurred is provided in the
Events list
submenu.
Navigation path
Diagnostics
menu →
Event logbook
submenu → Event list
F
I1091 Config. change
I1157 Mem.err. ev.list
F311 Electr. failure
/ ../Eventlist
0d01h19m10s
A0014008-EN
37
Taking the example of the local display
• A maximum of 20 event messages can be displayed in chronological order.
• If the
Extended HistoROM
application package (order option) is enabled in the device,
the event list can contain up to 100 entries .
The event history includes entries for:
Содержание Proline Cubemass C 300
Страница 215: ......