Technical data
Proline Cubemass C 300
202
Hauser
Manual
Additional parameter data record (complete parameter settings) in the integrated device
memory HistoROM backup for:
• Data backup function
Backup and subsequent restoration of a device configuration in the device memory
HistoROM backup
• Data comparison function
Comparison of the current device configuration with the device configuration saved in
the device memory HistoROM backup
Data transmission
Manual
Transfer of a device configuration to another device using the export function of the
specific operating tool, e.g. with FieldCare, DeviceCare or Web server: to duplicate the
configuration or to store in an archive (e.g. for backup purposes)
Event list
Automatic
• Chronological display of up to 20 event messages in the events list
• If the
Extended HistoROM
application package (order option) is enabled: up to 100
event messages are displayed in the events list along with a time stamp, plain text
description and remedial measures
• The events list can be exported and displayed via a variety of interfaces and operating
tools e.g. DeviceCare, FieldCare or Web server
Data logging
Manual
If the
Extended HistoROM
application package (order option) is enabled:
• Record up to 1
000 measured values via 1 to 4 channels
• User configurable recording interval
• Record up to 250 measured values via each of the 4 memory channels
• Export the measured value log via a variety of interfaces and operating tools e.g.
FieldCare, DeviceCare or web server
16.12 Certificates and approvals
Current certificates and approvals that are available for the product can be selected via the
Product Configurator at
www.endress.com
:
1. Select the product using the filters and search field.
2. Open the product page.
3. Select
Configuration
.
CE mark
The device meets the legal requirements of the applicable EU Directives. These are listed in
the corresponding EU Declaration of Conformity along with the standards applied.
Hauser confirms successful testing of the device by affixing to it the CE mark.
UKCA marking
The device meets the legal requirements of the applicable UK regulations (Statutory
Instruments). These are listed in the UKCA Declaration of Conformity along with the
designated standards. By selecting the order option for UKCA marking, Hauser
confirms a successful evaluation and testing of the device by affixing the UKCA mark.