Diagnostics and troubleshooting
Proline Cubemass C 300
160
Hauser
Diagnostic
number
Short text
Remedy instructions
Status
signal
[from the
factory]
Diagnostic
behavior
[from the
factory]
331
Firmware update failed
1. Update firmware of device
2. Restart device
F
Warning
332
Writing in HistoROM
backup failed
1. Replace user interface board
2. Ex d/XP: replace transmitter
F
Alarm
361
I/O module 1 to n faulty 1. Restart device
2. Check electronic modules
3. Change I/O module or main
electronics
F
Alarm
369
Matrix code scanner
defective
Replace matrix code scanner
F
Alarm
371
Temperature sensor
defective
Contact service
M
Warning
372
Sensor electronics
(ISEM) faulty
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module
(ISEM)
F
Alarm
373
Sensor electronics
(ISEM) faulty
Transfer data or reset device
F
Alarm
374
Sensor electronics
(ISEM) faulty
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module
(ISEM)
S
Warning
375
I/O- 1 to n
communication failed
1. Restart device
2. Check if failure recurs
3. Replace module rack inclusive
electronic modules
F
Alarm
378
Supply voltage ISEM
faulty
1. If available: Check connection cable
between sensor and transmitter
2. Replace main electronic module
3. Replace sensor electronic module
(ISEM)
F
Alarm
382
Data storage
1. Insert T-DAT
2. Replace T-DAT
F
Alarm
383
Memory content
Reset device
F
Alarm
387
HistoROM data faulty
Contact service organization
F
Alarm
Diagnostic of configuration
410
Data transfer failed
1. Retry data transfer
2. Check connection
F
Alarm
412
Processing download
Download active, please wait
C
Warning
431
Trim 1 to n required
Carry out trim
C
Warning
437
Configuration
incompatible
1. Update firmware
2. Execute factory reset
F
Alarm
438
Dataset different
1. Check data set file
2. Check device parameterization
3. Download new device
parameterization
M
Warning
441
Current output 1 to n
faulty
1. Check process
2. Check current output settings
S
Warning
442
Frequency output faulty 1. Check process
2. Check frequency output settings
S
Warning
443
Pulse output 1 to n
faulty
1. Check process
2. Check pulse output settings
S
Warning