Proline Cubemass C 300
Mounting
Hauser
25
Rupture disk
Process-related information: → 195.
L
WARNING
Danger from medium escaping!
Medium escaping under pressure can cause injury or material damage.
‣
Take precautions to prevent danger to persons and damage if the rupture disk is
actuated.
‣
Observe the information on the rupture disk sticker.
‣
Make sure that the function and operation of the rupture disk is not impeded through
the installation of the device.
‣
Do not use a heating jacket.
‣
Do not remove or damage the rupture disk.
The position of the rupture disk is indicated by a sticker affixed beside it.
RUPTURE DISK
i
1
A0029940
1
Rupture disk label
Wall mounting
L
WARNING
Incorrect sensor mounting
Risk of injury if measuring tube breaks
‣
The sensor should never be installed in a pipe in a way that it is freely suspended
‣
Using the base plate, mount the sensor directly on the floor, wall or ceiling.
‣
Support the sensor on a securely mounted support base (e.g. angle bracket).
The following mounting versions are recommended for the installation.
Vertical
• Mounted directly on a wall using the base plate, or
• Device supported on an angle bracket mounted on the wall
A0030286