Proline Cubemass C 300
Technical data
Hauser
203
Contact address Hauser UK:
Hauser Ltd.
Floats Road
Manchester M23 9NF
United Kingdom
RCM mark
The measuring system meets the EMC requirements of the "Australian Communications
and Media Authority (ACMA)".
Ex approval
The devices are certified for use in hazardous areas and the relevant safety instructions are
provided in the separate "Safety Instructions" (XA) document. Reference is made to this
document on the nameplate.
Functional safety
The measuring device can be used for flow monitoring systems (min., max., range) up to
SIL 2 (single-channel architecture; order code for "Additional approval", option LA) and SIL
3 (multi-channel architecture with homogeneous redundancy) and is independently
evaluated and certified in accordance with IEC 61508.
The following types of monitoring in safety equipment are possible:
• Mass flow
• Volume flow
• Density
Functional Safety Manual with information on the SIL device → 207
HART certification
HART interface
The measuring device is certified and registered by the FieldComm Group. The measuring
system meets all the requirements of the following specifications:
• Certified according to HART 7
• The device can also be operated with certified devices of other manufacturers
(interoperability)
Radio approval
The measuring device has radio approval.
For detailed information on the radio approval, see the Special Documentation
Additional certification
CRN approval
Some device versions have CRN approval. A CRN-approved process connection with a CSA
approval must be ordered for a CRN-approved device.
Tests and certificates
• EN10204-3.1 material certificate, wetted parts and sensor housing
• Pressure test, internal process, inspection certificate
• PMI test (XRF), internal procedure, wetted parts, test report