Proline Cubemass C 300
Mounting
Hauser
27
6.2
Mounting the measuring device
6.2.1
Required tools
For sensor
For flanges and other process connections: use a suitable mounting tool
6.2.2
Preparing the measuring device
1. Remove all remaining transport packaging.
2. Remove any protective covers or protective caps present from the sensor.
3. Remove stick-on label on the electronics compartment cover.
6.2.3
Mounting the measuring device
L
WARNING
Danger due to improper process sealing!
‣
Ensure that the inside diameters of the gaskets are greater than or equal to that of the
process connections and piping.
‣
Ensure that the seals are clean and undamaged.
‣
Secure the seals correctly.
1. Ensure that the direction of the arrow on the nameplate of the sensor matches the
flow direction of the medium.
2. Install the measuring device or turn the transmitter housing so that the cable entries
do not point upwards.
A0029263
6.2.4
Turning the transmitter housing
To provide easier access to the connection compartment or display module, the transmitter
housing can be turned.
Содержание Proline Cubemass C 300
Страница 215: ......
Страница 216: ...www addresses endress com 71574975 71574975...