Configure Remote Power
Management
Configure the Connect IT to connect to a power controller using a serial
port
Digi Connect IT® 16/48 User Guide
41
Connect a power controller to the Connect IT serial port
After you have configured a power management serial port on the Connect IT and configured the
power controller, you should connect the Connect IT and the power controller with a serial cable.
In this example, serial port 3 was configured for use with a power controller. See
.
1. Connect a serial cable to the serial port on the Connect IT that you configured for power
management.
2. Connect the other end of the serial cable to the serial port on the power controller.
3. Plug the power controller into a power source.
Configure the power controller and the outlets for use with a serial
port on the Connect IT
You can configure the power controller to communicate with a specific serial port on the Connect IT.
You can also configure the outlets on the power controller to work with a specific serial port on the
Connect IT, into which a device will be connected.
1.
.
2. Click
System
>
Power Controller Configuration
.
3. Select
Enable
.
4. In the
Monitor Interval
field, specify the number of seconds to wait between power controller
status checks.
5. Click
Add Controller
.
6. In the
Controller Name
field, enter a descriptive name.
7. From the
Controller Type
list box, select the appropriate controller type.
8. From the
Connection type
list box, select
Serial Port
.
9. In the
Serial port
field, select the port number from the list box. See
.
10. The entries in the following fields must match the information for the power controller. Refer
to your power controller manual for the correct entries:
Baud rate
,
Data bits
,
Parity
,
Stop
bits
, and
Flow control
.
11. Configure the outlets on the power controller that can be controlled by the port.
a. In the
Name
field, enter a descriptive name. You can type over the default name.
b. In the
Index
field, enter the appropriate outlet index. Refer to the manual for your power
controller to determine the outlet index.
c. From the
Controlled Device
list box, select a serial port. This is the port you will use to
complete the connection between the Connect IT and the 3rd-party device plugged into
the outlet on the power controller. In this example, outlet 1 is configured for serial port 5.
Note
The serial port you configure for an outlet must be configured for
Remote Access
mode.
d. Repeat the process to configure additional outlets. You can click
Add Outlet
to add
another outlet.
12. Click
Apply
.
Содержание Connect IT 16
Страница 1: ...Digi Connect IT 16 48 User Guide Firmware version 21 2 ...
Страница 157: ...Interfaces Bridging Digi Connect IT 16 48 User Guide 157 8 Click Apply to save the configuration and apply the change ...
Страница 440: ...Services Configure the ping responder service Digi Connect IT 16 48 User Guide 440 iperf Done ...