12. If
Enable watchdog
is enabled:
a. (Optional) For
Restart Timeout
, type the amount of time to wait before restarting the
connection to the remote cloud services, once the connection is down.
Allowed values are any number of hours, minutes, or seconds, and take the format
number
{
h|m|s
}.
For example, to set
Restart Timeout
to ten minutes, enter
10m
or
600s
.
The minimum value is 30 minutes and the maximum is 48 hours. If not set, this option is
disabled. The default is 30 minutes.
b. (Optional) For
Reboot Timeout
, type the amount of time to wait before rebooting the
device, once the connection to the remote cloud servicesis down. By default, this option is
not set, which means that the option is disabled.
Allowed values are any number of hours, minutes, or seconds, and take the format
number
{
h|m|s
}.
For example, to set
Reboot Timeout
to ten minutes, enter
10m
or
600s
.
The minimum value is 30 minutes and the maximum is 48 hours. If not set, this option is
disabled. The default is disabled.
13. (Optional) Enable
Locally authenticate CLI
to require a login and password to authenticate
the user from the remote cloud services CLI. If disabled, no login prompt will be presented and
the user will be logged in as
admin
. The default is disabled.
14. (Optional) Configure the Connect IT 16/48 device to communicate with remote cloud services
by using SMS:
a. Click to expand
Short message service
.
b.
Enable
SMS messaging.
c. For
Destination phone number
, type the phone number for the remote cloud services.
d. (Optional) Type the
Service identifier
.
15. (Optional) Configure the Connect IT 16/48 device to communicate with remote cloud services
by using an HTTP proxy server:
a. Click to expand
HTTP Proxy
.
b.
Enable
the use of an HTTP proxy server.
c. For
Server
, type the hostname of the HTTP proxy server.
d. For
Port
, type or select the port number on the HTTP proxy server that the device should
connect to. The default is
2138
.
16. Click
Apply
to save the configuration and apply the change.
Command line
1. Log into the Connect IT 16/48 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
admin
to access the Admin CLI.
Содержание Connect IT 16
Страница 1: ...Digi Connect IT 16 48 User Guide Firmware version 21 2 ...
Страница 157: ...Interfaces Bridging Digi Connect IT 16 48 User Guide 157 8 Click Apply to save the configuration and apply the change ...
Страница 440: ...Services Configure the ping responder service Digi Connect IT 16 48 User Guide 440 iperf Done ...