Monitoring
Configure NetFlow Probe
Digi Connect IT® 16/48 User Guide
631
WebUI
1. Log into the Connect IT 16/48 WebUI as a user with full Admin access rights.
2. On the menu, click
System
. Under
Configuration
, click
Device Configuration
.
The
Configuration
window is displayed.
3. Click
Monitoring
>
NetFlow probe
.
4.
Enable
NetFlow probe.
5.
Protocol version:
Select the
Protocol version
. Available options are:
n
NetFlow v5
—Supports IPv4 only.
n
NetFlow v9
—Supports IPv4 and IPv6.
n
NetFlow v10 (IPFIX)
—Supports both IPv4 and IPv6 and includes IP Flow Information
Export (IPFIX).
The default is
NetFlow v10 (IPFIX)
.
6. Enable
Flow sampler
by selecting a sampling technique. Flow sampling can reduce flow
processing and transmission overhead by providing a representative subset of all flows.
Available options are:
n
None
—No flow sampling method is used. Each flow is accounted.
n
Deterministic
—Selects every
n
th flow, where
n
is the value of
Flow sampler
population
.
n
Random
—Randomly selects one out of every
n
flows, where
n
is the value of
Flow
sampler population
.
n
Hash
—Randomly selects one out of every
n
flows using the hash of the flow key, where
n
is the value of
Flow sampler population
.
7. For
Flow sampler population
, if you selected a flow sampler, enter the number of flows for
the sampler. Allowed value is any number between
2
and
16383
. The default is
100
.
8. For
Inactive timeout
, type the the number of seconds that a flow can be inactive before sent
to a collector. Allowed value is any number between
1
and
15
. The default is
15
.
9. For
Active timeout
, type the number of seconds that a flow can be active before sent to a
collector. Allowed value is any number between
1
and
1800
. The default is
1800
.
10. For
Maximum flows
, type the maximum number of flows to probe simultaneously. Allowed
value is any number between
0
and
2000000
. The default is
2000000
.