System administration
Erase device configuration and reset to factory defaults
Digi Connect IT® 16/48 User Guide
599
Command line
1. Log into the Connect IT 16/48 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
admin
to access the Admin CLI.
2. At the command line, type
config
to enter configuration mode:
> config
(config)>
3. Set the reboot time:
(config>> system schedule reboot_time
time
(config)>
where
time
is the time of the day that the device should reboot, using the format
HH
:
MM
. For
example, the set the device to reboot at two in the morning every day:
(config>> system schedule reboot_time 02:00
(config)>
If a value is set for
reboot_time
but the device is unable to synchronize its time with an NTP
server, the device will reboot after it has been up for 24 hours. See
for information
about configuring NTP servers.
4. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
5. Type
exit
to exit the Admin CLI.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
quit
to disconnect from the device.
Erase device configuration and reset to factory defaults
You can erase the device configuration in the WebUI, at the command line, or by using the
Reset
button on the device. Erasing the device configuration performs the following actions:
n
Clears all configuration settings. When the device restarts, it uses the factory default
configuration.
n
Deletes all user files.
n
Clears event and system log files.
Additionally, if the
Reset
button is used to erase the configuration, pressing the
Reset
button a second
time immediately after the device has rebooted: