SiAUY361411EA
Flow Charts for Troubleshooting
Troubleshooting
132
Is Ribbed Belt Non-Defective?
Is Crank Pulse Sensor
Operating Normally?
Is Mixer Operating Normally?
Is Breather Hose
Non-Defective?
Are Compressor Clutches
Operating Normally When
Unit Is Running?
Are You Sure There Is
No Tendency Of Misfire
When Unit Is Running?
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
Check Ribbed Belt.
Check Crank Pulse Sensor.
Check Gas Pressure.
(whether Gas Pressure is
stable)
2
Engine Overspeed
Error
code
E1
Description
of the failure
Sub-code 0: While the unit is running, the engine speed exceeds the maximum speed specific to the model
plus the regulated speed specific to the model.
Possible
causes
of the failure
Rib belt broken; mixer malfunctioning; clutch malfunctioning; crank pulse sensor gap incorrect;
blow-by system failure; gas pressure abnormally fluctuating; ignition system instable
Flow chart
Check Breather Hose.
Check Clutches.
Check Ignition System.
Check Mixer.
025865-00E
Содержание GYEQ20AN
Страница 1: ...Heat Recovery R 410A 50 Hz GYEQ20 30AN SiAUY361411EA Service Manual Gas Heat Pump Air Conditioner...
Страница 21: ...SiAUY361411EA External Diagrams Device Overview 10 3 External Diagrams GYEQ20AN 3PA003981A Unit mm...
Страница 22: ...External Diagrams SiAUY361411EA 11 Device Overview GYEQ30AN 3PA003980A Unit mm...
Страница 58: ...Installation Work Manual SiAUY361411EA 47 Device Overview 0FGHP EN0801 DGJ002...
Страница 60: ...Installation Work Manual SiAUY361411EA 49 Device Overview 0FGHP EN0801 DGJ002...
Страница 225: ...SiAUY361411EA Maintenance Maintenance Service Data 214...