Connecting a boiler fitted with a control panel with an input
TAM
Fig.67
Boiler fitted with a control panel with an input TAM
BUS
MW-C003336-1
TAM
2 x 0,75 mm2
170
170
171
A
B
C
1 Domestic hot water load pump power supply
TAM Room thermostat
7.5.11 Connecting a swimming pool
The swimming pool is not heated when the contact is open (factory set
ting). Only the frost protection continues to run.
The electrical connection of a swimming pool is made to the optional
SCB-04 PCB.
1. Connect the secondary pump from the swimming pool to the ter
minal block.
2. Connect the temperature sensor from the swimming pool to the
TFlowterminal block.
3. Connect the primary pump from the swimming pool to the
termi
nal block.
4. Connect the swimming pool heating cut-off control to the R-Bus ter
minal block.
Fig.68
Connecting a swimming pool
MW-6000381-5
1
2
3
4