Fault
code
Message
Description
E02.24
System flow locking active
System water flow locking active
No circulation:
Check that the circulation pump is
working.
Check that the valves and thermostatic
valves are open.
Check the wiring.
Check the pump supply: if the pump
does not work, replace it.
Too much air
Completely vent the indoor module
and the installation for optimum run
ning.
Check that the automatic air vents are
properly open (also check the hydro
block).
Completely vent the indoor module and
the installation for optimum running.
Incorrect wiring: check the electrical con
nections.
Flow meter:
Check the electrical connections and
the direction of the flow meter (arrow
to the right).
Replace the flow meter if necessary.
12.2.3 Alarm codes
An alarm code is a temporary heat pump status, resulting from the detec
tion of an anomaly. If an alarm code still remains after several automatic
start-up attempts, the system goes into fault mode.
Tab.75 List of alarm codes
Error code
Message
Description
A02.06
Water Press Warning
Water Pressure Warning active
A02.18
OBD Error
Object Dictionary Error
A02.22
System flow warning
System water flow warning active
A02.55
Inval or miss SerNR
Invalid or missing device serial number
12.3 Accessing the error memory
The error and fault codes are listed together in the memory.
1. Access the menus by pressing the two keys on the right simultane
ously.
Fig.129
MW-2000369-1
12 Troubleshooting
7685645 - v04 - 07032018
AWHP-2 iMPI
111