1. Go to stop mode by pressing the
key.
2. Select the heating mode by pressing the key.
3. Confirm by pressing the
key.
4. Select the heating shut-down pressing the key.
The screen displays: .
The frost protection function continues to run.
The heating and cooling have been shut down.
Important
Press the key to restart the appliance: the screen will
display .
5. Confirm by pressing the
key.
6. Go back to the main display by pressing the
h
key.
Important
The display disappears after a few seconds of inactivity.
9.3.2
Shutting down the cooling function
Important
If the heating function is shut off, then the cooling will also be shut
off.
1. Access the menu.
2. Confirm access by pressing the
key.
3. Select CIRCA or CIRCB by pressing the or key.
4. Confirm the selection by pressing the
key.
5. Select TP.C by pressing the or keys.
6. Confirm the selection by pressing the
key.
7. Modify the timer program to stop cooling.
9.4
Frost Protection
If the temperature of the heating water in the heat pump falls too much,
the integrated protection device switches itself on. This device functions as
follows:
If the water temperature is lower than 5°C, the circulating pump starts
up.
If the water temperature is lower than 3°C, the back-up starts up.
If the water temperature is higher than 10°C, the back-up shuts down
and the circulating pump continues to run for a short time.
Fig.99
MW-5000027-4
Fig.100
MW-5000133-3
Fig.101
MW-5000134-3
9 Operation
74
AWHP-2 iMPI
7685645 - v04 - 07032018