3. Select the AP103 parameter corresponding to language selection by
pressing the or keys.
4. Confirm by pressing the
key.
5. Access the languages available by pressing the
key.
6. Select the language by pressing the or keys until the desired
language is displayed.
7. Confirm by pressing the
key.
8. Go back to the main display by pressing the
h
key.
10.5.2 Selecting the type of outdoor unit and the type of back-up
(CN1 et CN2)
1. Go to the Installer menu.
2. Access the Installer menu: enter the code 0012 by pressing the
and keys.
3. Confirm access by pressing the
key.
4. Access the EHC–04 PCB parameters by pressing the or key.
5. Select the CNF menu (control panel reset) by pressing the or
keys.
6. Confirm by pressing the
key.
7. Refer to the table below and enter the values corresponding to the
type of outdoor unit and the type of back-up by pressing on the or
keys.
8. Confirm the selection by pressing the
key.
9. Go back to the main display by pressing the
h
key.
CNF menu
The CNF menu is used to configure the hybrid heat pump according to the
type of back-up and the output of the outdoor unit installed.
Tab.55 Value of the CN1 and CN2 parameters with a hydraulic back-up
Output of the outdoor unit
CN1
CN2
4.5 kW
18
3
Fig.107
MW
-5
0
0
0
4
0
6
-2
Fig.108
MW
-5
0
0
0
4
0
5
-2
Fig.109
MW
-5
0
0
0
4
0
7
-2
Fig.110
MW
-5
0
0
0
0
2
6
-5
Fig.111
MW
-6
0
0
0
3
6
7
-3