5.2.2
Special precautions for the connection of the heating cir
cuit
When making the connection, it is imperative that the standards and corre
sponding local directives be respected.
Caution
The hydraulic installation must be capable of handling a minimum
flow rate at all times:
If radiators are connected directly to the heating circuit: install a
differential valve between the indoor module and the heating cir
cuit.
Leave one heating circuit without a thermostatic valve and/or
without a solenoid valve.
Fit drainage valves between the indoor module and the heating
circuit.
Install a filter on the heating return circuit.
5.3
Choice of the location
Decide on the ideal location, bearing in mind the space required by the
heat pump and any legal directives.
Install the heat pump's indoor module on a solid, stable structure capa
ble of bearing the weight of the heat pump when full of water and fitted
with its various accessories.
Install the indoor module as close as possible to the draw-off points in
order to minimise energy losses through the pipes.
Install the heat pump's outdoor module on a solid, stable structure.
Caution
The indoor module must be installed on frost-free premises.
5.3.1
Data plate
The data plates identify the product and provide the following important in
formation.
The data plates must be accessible at all times.
Important
Never remove or cover labels and data plates affixed to the appli
ances. Labels and data plates must be legible throughout the en
tire lifetime of the appliance.
Damaged or illegible instructions and warning stickers must be re
placed immediately.
5 Before installation
7685645 - v04 - 07032018
AWHP-2 iMPI
29