Make the electrical connections on the appliance in accordance with the
information given in the electrical schematics delivered with the appli
ance,
Make the electrical connections on the appliance in accordance with the
recommendations of these instructions.
Important
Earthing must comply with the prevailing installation standards.
Caution
The installation must be fitted with a main switch.
Three phase models must always be fitted with neutral.
Caution
Power the appliance via a circuit that includes an omnipolar switch
with contact opening distance of 3 mm or more.
Single phase models: 230 V (+6%/-10%) 50 Hz
Three-phase models: 400 V (+6%/-10%) 50 Hz
When making electrical connections to the mains, respect the following
polarities.
Tab.23
Colour of the wire
Polarity
Brown wire
Live
Blue wire
Neutral
Green/yellow wire
Earth
Caution
Secure the cable with the cable clamp provided. Be careful that
you do not invert any of the wires.
7.5.2
Routing the cables
1 Cables for 230/400 V circuits and electrical back-up
2 0 - 40 V sensor cables
Fig.54
0-40V
MW-5000755-1
1
2
230-400V
7 Installation
52
AWHP-2 iMPI
7685645 - v04 - 07032018