Tab.2
Conditions of use
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Limit water operating temperatures in heating mode
+18 °C/+60 °C
+18 °C/+60 °C
Limit outdoor air operating temperatures in heating mode
-20 °C/+35 °C
-20 °C/+35 °C
Limit water operating temperatures in cooling mode for uninsulated models
+18 °C/+25 °C
+18 °C/+25 °C
Limit water operating temperatures in cooling mode for insulated models
+7°C / +25°C
+7°C / +25°C
Limit outdoor air operating temperatures in cooling mode
+7 °C/+40 °C
+7 °C/+40 °C
Tab.3
Heating mode: outside air tempe7°C, water temperature at the 35°C. Performances in accordance with
EN 14511-2.
Measure
ment type
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Heat output kW
4.60
5.79
8.26
11.39
11.39
14.65
14.65
Coefficient
of Perform
ance (COP)
5.11
4.05
4.27
4.65
4.65
4.22
4.22
Absorbed
electrical
power
kWe
0.90
1.43
1.93
2.45
2.45
3.47
3.47
Nominal wa
ter flow rate
(ΔT = 5K)
m
3
/hour
0.88
1.13
1.53
1.96
1.96
2.53
2.53
Tab.4
Heating mode: outside air tempe2°C, water temperature at the 35°C. Performances in accordance with
EN 14511-2.
Measure
ment type
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Heat output kW
3.47
3.65
5.3
10.19
10.19
12.90
12.90
Coefficient
of Perform
ance (COP)
3.97
3.23
3.46
3.20
3.20
3.27
3.27
Absorbed
electrical
power
kWe
0.88
1.13
1.53
3.19
3.19
3.94
3.94
Tab.5
Cooling mode: outside air tempe35°C, water temperature at the 18°C. Performances in accordance
with EN 14511-2.
Measure
ment type
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Cooling out
put
kW
3.80
4.69
7.90
11.16
11.16
14.46
14.46
Energy effi
ciency ratio
(EER)
4.28
4.09
3.99
4.75
4.75
3.96
3.96
Absorbed
electrical
power
kWe
0.89
1.15
2.00
2.35
2.35
3.65
3.65
3 Technical specifications
7685645 - v04 - 07032018
AWHP-2 iMPI
13