Product name
AWHP-2 iMPI
AWHP 4.5 MR
AWHP-2 iMPI
AWHP 6 MR-3
Supplementary heater
Rated heat output
Psup
kW
0.0
0.0
Type of energy input
Electricity
Electricity
Other specifications
Capacity control
Variable
Variable
Sound power level, indoors - outdoors
L
WA
dB
49 – 61
49 – 62
Annual energy consumption under average
conditions
Q
HE
kWh
2353
2124
Annual energy consumption under colder con
ditions
Q
HE
kWh
4483
3721
Annual energy consumption under warmer
conditions
Q
HE
kWh
1249
1492
Rated air flow rate, outdoors for air-to-water
heat pumps
—
m
3
/h
2100
2100
(1) The rated heat output
Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
(2) If
Cdh is not determined by measurement, the default degradation coefficient is Cdh = 0.9.
Tab.10 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name
AWHP-2 iMPI
AWHP 8 MR-2
AWHP-2 iMPI
AWHP 11
MR-2
AWHP 11
TR-2
AWHP-2 iMPI
AWHP 16
MR-2
AWHP 16
TR-2
Air-to-water heat pump
Yes
Yes
Yes
Water-to-water heat pump
No
No
No
Brine-to-water heat pump
No
No
No
Low-temperature heat pump
No
No
No
Equipped with a supplementary heater
Yes
Yes
Yes
Heat pump combination heater
No
No
No
Rated heat output under average conditions
(1)
Prated
kW
6
6
9
Rated heat output under colder conditions
Prated
kW
6
4
7
Rated heat output under warmer conditions
Prated
kW
6
8
13
Declared capacity for heating for part load at an
indoor temperature of 20°C and outdoor tempera
ture
T
j
T
j
= -7°C
Pdh
kW
5.6
5.9
9.0
T
j
= +2°C
Pdh
kW
2.9
5.3
6.5
T
j
= +7°C
Pdh
kW
6.4
9.0
12.9
T
j
= +12°C
Pdh
kW
4.3
7.7
10.0
T
j
= bivalent temperature
Pdh
kW
5.2
6.3
8.8
T
j
= operation limit temperature
Pdh
kW
5.2
6.3
8.8
Bivalent temperature
T
biv
°C
-10
-10
-10
Degradation coefficient
(2)
Cdh
—
1.0
1.0
1.0
3 Technical specifications
16
AWHP-2 iMPI
7685645 - v04 - 07032018