3. Pivot the PCB support for routing the cables and connecting certain
options.
Connecting the cables to the PCBs
Use original connectors inserted into the various terminal blocks.
The connectors are keyed.
If there are no connectors on the terminal block to be used, use the con
nector provided with the kit.
Before feeding the cables into the cable feed-throughs, use the coloured
labels provided with some accessories to mark each end of the cable
with the same colour.
1. Insert and screw down the wires in the corresponding connector in
puts.
2. Insert the connector into the corresponding terminal block.
3. Feed the cable into the cable duct and adjust the length of the cable
accordingly. Lock it in position with a cable clamp or a traction ar
rester device.
Caution
Danger of electric shock: the length of the conductors between the
traction arrester device and the terminal blocks must be such that
the active conductors are put under tension before the earth con
ductor.
Fig.58
MW-3000597-01
3
Fig.59
Mounting a connector
MW-6000148-2
1
2
7 Installation
7685645 - v04 - 07032018
AWHP-2 iMPI