Parameter
Description
Unit
EHC-04
SCB04-B
AC027
Counter that shows the number of pump starts
-
X
AC028
Total working time of the first stage of backup
hours
X
AC029
Total working time of the second stage of backup hours
X
AC030
Total startings of the first stage of backup
-
X
AC031
Total startings of the second stage of backup
-
X
DC002
Numbers of Domestic Hot Water diverting valve
cycles
-
X
DC003
Number of hours during which the diverting valve
is in DHW position
hours
X
DC004
Number of compressor start-ups during domestic
hot water production
X
DC005
Number of compressor start-ups
X
PC002
Number of compressor start-ups
-
-
X
PC003
Number of compressor operating hours
hours
X
CODE
Enter the installer code to access the following pa
rameters.
X
AC002
Number of hours that the appliance has been
producing energy since last service
hours
X
AC003
Number of hours since the previous servicing of
the appliance
hours
X
AC004
Number of generator startings since the previous
servicing.
X
AC013
Seasonal coefficient of performance
X
SERVICE
Resetting the maintenance service
CLR: the AC002, AC003, and AC004 counters are
reset to zero.
X
10.3.2 COUNTERS, TIME PROG, CLOCK \CIRCA, CIRCB
and DHW menus
Tab.50
Menu
Description
CIRCA
TP.H: Timer programming for heating
06:00 - 23:00 ON
23:00 - 06:00 OFF
TP.C: Timer programming for cooling
14:00 - 23:00 ON
23:00 - 14:00 OFF
CIRCB
Timer programming for heating
06:00 - 23:00 ON
23:00 - 06:00 OFF
DHW
Timer programming for domestic hot water
06:00 - 23:00 ON
23:00 - 06:00 OFF
10 Settings
86