ADV parameter
Description of the ADV advanced parameters
Factory setting
EHC–04
PP016
Maximum central heating pump speed (%)
Maximum pump speed in heating mode
Can be set from 20 to 100%
100%
PP018
Minimum central heating pump speed (%)
Minimum pump speed in heating mode
Can be set from 20 to 100%
30%
AD
Auto detect
available
CNF
Reset factory parameters
See the data plate
ADV
ADV advanced parameters
not available
10.3 COUNTERS /TIME PROG / CLOCK menus
Tab.47 List of sub-menus
Sub-menu
Description
CNT
COUNTERS
CIRCA
Timer programming for the main heating circuit
CIRCB
Timer programming for the additional heating circuit B
DHW
Timer programming for the domestic hot water circuit
CLK
Setting the clock and the date
10.3.1 COUNTERS, TIME PROG, CLOCK \CNT menus
Tab.48 Choosing the menu
Counters
Selection
Circuit A counters
Choose the EHC-04 menu
Circuit B counters
Choose the SCB04-B menu
Counters connected to the opera
tion of the heat pump
Choose the EHC-04 menu
Tab.49 Available counters
Parameter
Description
Unit
EHC-04
SCB04-B
AC001
Number of hours that the appliance has been on
mains power
hours
X
X
AC005
Energy consumed for central heating
kWh
X
AC006
Energy consumed for domestic hot water
Wh
X
AC007
Energy consumed for cooling
Wh
X
AC008
Energy delivered for central heating
kWh
X
AC009
Energy delivered for domestic hot water
kWh
X
AC010
Energy delivered for cooling
kWh
X
AC013
Seasonal COP
X
AC026
Counter that shows the number of pump running
hours
hours
X
10 Settings
7685645 - v04 - 07032018
AWHP-2 iMPI