5-11
Chapter 5. Screens
(10)
(12)
(14)
(15)
(13)
(9)
(11)
(9) Graph icon
Touching this icon displays the graph screen.
(10) DO display
Displays the statuses of the DO1 to 7 terminals.
A green number shows ON status, a gray number shows OFF status, and "-"
indicates the DI function.
Touching this portion of the screen displays the DI/DO monitor screen.
(11) Alarm 1 icon
The light blue icon shows that no alarm occurs. Touching this icon displays the
block alarm screen.
(12) Mode button
Touching this icon displays the mode change screen.
(13) View change button
Touching this icon changes the display. Available values can be viewed from
among the MANUAL MV, Cool MV and Heat MV of heating/cooling control,
MFB, CT input, VT input, and resistance calculated from CT input and VT
input.
6-1, "Operation Display List” 1-loop monitor screen (p. 6-2).
(14) Change button
Pressing this button displays the monitor screen for the next loop number. After
the monitor screen for the last loop number has been displayed, the multi-loop
monitor screen is displayed. If there is only one loop, the monitor screen does
not change.
Holding down this button displays the touch panel calibration screen.
(15) Menu button
Pressing this button displays the parameter bank menu screen.
Holding down the button turns ON the key lock, in which case the parameter
bank menu screen cannot be displayed.