Error messages in MS-DOS
100
Controller B1 v3.0 – 16 Troubleshooting
Remedy
: Run the“B1 Unload” program from the “AVM” pro-
gram group to unload the ISDN-Controller and then start the
test program again.
Error messages in MS-DOS
Error message:
“
Controller-xx with I/O address <xxx> could
not be found”
Possible cause
: The position of the jumper that sets the I/O
address on the ISDN-Controller does not correspond to the
entry in the “B1 Setup” program, the I/O address is used by
another hardware device (such as a network adapter), or the
hardware is not installed.
Remedy:
Check which I/O address is available in your com-
puter and set the jumper on the ISDN-Controller accordingly
(see the section “Setting the I/O Address” on page 14). Then
enter the new I/O address in the driver software by starting
the “B1 Setup” program from the “AVM” program group.
Then reload the ISDN-Controller with “
ibase.bat
”.
Error message: “Installation Error. Interrupt <xx> not
available.”
Possible cause
: The AVM ISDN-Controller B1 v3.0 and anoth-
er hardware device (like a sound card) are set to the same in-
terrupt.
Remedy
: Check which interrupts (IRQs) are available in your
system by using the MSD.EXE program in the Windows direc-
tory. Then start the “B1 Setup” program from the “AVM” pro-
gram group and define another interrupt for the ISDN-Con-
troller. Then reload the ISDN-Controller with “ibase.bat”.
Error message:
“
Error in the configuration file. Incorrect B1
controller type.”
Possible cause
: Different types of controllers (ISDN-Control-
lers for the ISA and PCI buses) are combined in your system.
During the installation of the additional controller, the file
ISDNLOAD.CFG was not changed correctly.
HB_B1V30.book Seite 100 Mittwoch, 7. Februar 2001 3:19 15