Figure 40-4. Feedback Input Selection
Linked LUT (LINK)
When selected (LUTCTRLx.INSELy=LINK), the subsequent LUT output is used as the LUT input (e.g.,
LUT2 is the input for LUT1), as shown in this figure:
Figure 40-5. Linked LUT Input Selection
CTRL
(ENABLE)
LUT0
SEQ 0
LUT1
CTRL
(ENABLE)
LUT2
SEQ 1
LUT3
CTRL
(ENABLE)
LUT(2n – 2)
SEQ n
LUT(2n-1)
Internal Events Inputs Selection(EVENT)
Asynchronous events from the Event System can be used as input selection, as shown in
.
For each LUT, one event input line is available and can be selected on each LUT input. Before enabling
the event selection by writing LUTCTRLx.INSELy=EVENT, the Event System must be configured first.
The CCL includes an edge detector. When the event is received, an internal strobe is generated when a
rising edge is detected. The pulse duration is one GCLK_CCL clock cycle. The following steps ensure
proper operation: