36.8.5. Fault Control A and B
Name:
FCTRLA, FCTRLB
Offset:
0x0C + n*0x04 [n=0..1]
Reset:
0x00000000
Property:
PAC Write-Protection, Enable-Protected
Bit
31
30
29
28
27
26
25
24
FILTERVAL[3:0]
Access
R/W
R/W
R/W
R/W
Reset
0
0
0
0
Bit
23
22
21
20
19
18
17
16
BLANKVAL[7:0]
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
Bit
15
14
13
12
11
10
9
8
CAPTURE[2:0]
CHSEL[1:0]
HALT[1:0]
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
Bit
7
6
5
4
3
2
1
0
RESTART
BLANK[1:0]
QUAL
KEEP
SRC[1:0]
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
Bits 27:24 – FILTERVAL[3:0]: Recoverable Fault n Filter Value
These bits define the filter value applied on MCEx (x=0,1) event input line. The value must be set to zero
when MCEx event is used as synchronous event.
Bits 23:16 – BLANKVAL[7:0]: Recoverable Fault n Blanking Value
These bits determine the duration of the blanking of the fault input source. Activation and edge selection
of the blank filtering are done by the BLANK bits (FCTRLn.BLANK).
When enabled, the fault input source is internally disabled for BLANKVAL* prescaled GCLK_TCC periods
after the detection of the waveform edge.
Bits 14:12 – CAPTURE[2:0]: Recoverable Fault n Capture Action
These bits select the capture and Fault n interrupt/event conditions.
Table 36-8. Fault n Capture Action
Value
Name
Description
0x0
DISABLE Capture on valid recoverable Fault n is disabled
0x1
CAPT
On rising edge of a valid recoverable Fault n, capture counter value on channel
selected by CHSEL[1:0].
INTFLAG.FAULTn flag rises on each new captured value.