![ABB Relion RES670 Скачать руководство пользователя страница 565](http://html.mh-extra.com/html/abb/relion-res670/relion-res670_technical-manual_4485565.webp)
Name
Values (Range)
Unit
Step
Default
Description
NomValue03
0.0 - 999999.9
-
0.1
0.0
Nominal value for analog channel 3
UnderTrigOp03
Disabled
Enabled
-
-
Disabled
Use under level trigger for analog channel 3
(on) or not (off)
UnderTrigLe03
0 - 200
%
1
50
Under trigger level for analog channel 3 in %
of signal
OverTrigOp03
Disabled
Enabled
-
-
Disabled
Use over level trigger for analog channel 3
(on) or not (off)
OverTrigLe03
0 - 5000
%
1
200
Overtrigger level for analog channel 3 in % of
signal
NomValue04
0.0 - 999999.9
-
0.1
0.0
Nominal value for analog channel 4
UnderTrigOp04
Disabled
Enabled
-
-
Disabled
Use under level trigger for analog channel 4
(on) or not (off)
UnderTrigLe04
0 - 200
%
1
50
Under trigger level for analog channel 4 in %
of signal
OverTrigOp04
Disabled
Enabled
-
-
Disabled
Use over level trigger for analog channel 4
(on) or not (off)
OverTrigLe04
0 - 5000
%
1
200
Over trigger level for analog channel 4 in % of
signal
NomValue05
0.0 - 999999.9
-
0.1
0.0
Nominal value for analog channel 5
UnderTrigOp05
Disabled
Enabled
-
-
Disabled
Use under level trigger for analog channel 5
(on) or not (off)
UnderTrigLe05
0 - 200
%
1
50
Under trigger level for analog channel 5 in %
of signal
OverTrigOp05
Disabled
Enabled
-
-
Disabled
Use over level trigger for analog channel 5
(on) or not (off)
OverTrigLe05
0 - 5000
%
1
200
Over trigger level for analog channel 5 in % of
signal
NomValue06
0.0 - 999999.9
-
0.1
0.0
Nominal value for analog channel 6
UnderTrigOp06
Disabled
Enabled
-
-
Disabled
Use under level trigger for analog channel 6
(on) or not (off)
UnderTrigLe06
0 - 200
%
1
50
Under trigger level for analog channel 6 in %
of signal
OverTrigOp06
Disabled
Enabled
-
-
Disabled
Use over level trigger for analog channel 6
(on) or not (off)
OverTrigLe06
0 - 5000
%
1
200
Over trigger level for analog channel 6 in % of
signal
NomValue07
0.0 - 999999.9
-
0.1
0.0
Nominal value for analog channel 7
UnderTrigOp07
Disabled
Enabled
-
-
Disabled
Use under level trigger for analog channel 7
(on) or not (off)
UnderTrigLe07
0 - 200
%
1
50
Under trigger level for analog channel 7 in %
of signal
OverTrigOp07
Disabled
Enabled
-
-
Disabled
Use over level trigger for analog channel 7
(on) or not (off)
Table continues on next page
1MRK 511 408-UUS A
Section 16
Monitoring
Phasor measurement unit RES670 2.2 ANSI
559
Technical manual
Содержание Relion RES670
Страница 1: ...RELION 670 SERIES Phasor measurement unit RES670 Version 2 2 ANSI Technical manual ...
Страница 2: ......
Страница 276: ...270 ...
Страница 306: ...300 ...
Страница 360: ...354 ...
Страница 406: ...400 ...
Страница 614: ...608 ...
Страница 732: ...726 ...
Страница 748: ...742 ...
Страница 884: ...878 ...
Страница 932: ...926 ...
Страница 933: ...927 ...